4
Table 4. Mechanical Characteristics
Mechanical Characteristics over Recommended Operating Range, typical at 25 °C
Parameter Symbol Condition
Values
UnitsMin Typ. Max
Rotational Life
[1]
R
LIFE
Rotational Speed= 100RPM 2x10
5
cycles
Switch Click Life
[1]
C
LIFE
Push Location = on cover top, at switch location
Push Force = 200gf
5 x10
5
times
Permissible Rotational Angle q
A
360 °m
5-way switch button
-Stroke
-Operation force
0.19
200
mm
gf
Overall Mass M
OVR
0.002 Kg
Notes:
1. Options with higher rotational life and switch click life are available, please refer to factory.
Table 5. Encoding Characteristics
Encoding Characteristics over Recommended Operating Range, typical at 25°C. The typical values are average over the
full rotation.
Parameter Symbol Condition
Values
UnitsMin Typ. Max
Output Resolution N 45 CPR
Pulse width Error ∆P 50 °e
Logic State Width Error ∆S 50 °e
Phase Error ∆f 15 °e