Expand menu
Hello, Sign in
My Account
0
Cart
Home
Products
Sensors
Semiconductors
Passive Components
Connectors
Power
Electromechanical
Optoelectronics
Circuit Protection
Integrated Circuits - ICs
Main Products
Manufacturers
Blog
Services
About OMO
About Us
Contact Us
Check Stock
MAX1233ETI+T
P1-P3
P4-P6
P7-P9
P10-P12
P13-P15
P16-P18
P19-P21
P22-P24
P25-P27
P28-P30
P31-P33
P34-P36
P37-P39
P40-P42
P43-P44
MAX1233/MAX1234
±15kV ESD-Pr
otected T
ouch-Scr
een
Contr
ollers Include DAC and Keypad Contr
oller
______________________________________________________________________________________
37
YES
SCREEN
TOUCH
ST
ART CLOCK
GO TO
HOST
-INITIA
TED
SCAN
(FIGURE 24)
NO
YES
POWER UP ADC
YES
SET
PENIRQ LOW
ARE THERE
UNREAD SCAN
RESUL
TS?
NO
CONVERT X- COORDINA
TES
IS TOUCH-SCREEN
SETTLING DONE?
NO
IS DA
T
A
AVERAGING DONE?
TURN ON DRIVERS: X+, X-
YES
NO
POWER UP ADC
CONVERT Y
- COORDINA
TES
IS TOUCH-SCREEN
SETTLING DONE?
YES
NO
STORE Y
- COORDINATES IN
Y
- REGISTER
POWER DOWN ADC
IS DA
T
A
AVERAGING DONE?
CONVERT Z
1
- COORDINA
TES
YES
NO
IS DA
T
A
AVERAGING DONE?
IS PENSTS
BIT = 1?
SET BUSY LOW
TURN ON DRIVERS: Y+, Y
-
DONE
TURN OFF CLOCK
SET BUSY HIGH
STORE Z
1
- COORDINA
TES
IN Z
1
- REGISTER
YES
NO
IS DA
T
A
AVERAGING DONE?
CONVERT Z
2
COORDINA
TES
STORE Z
2
- COORDINA
TES
IN Z
2
- REGISTER
RESET PENIRQ HIGH
PENIRQ-INITIA
TED
X, Y
, AND Z SCREEN SCAN
POWER UP ADC
STORE X- COORDINA
TES
IN X- REGISTER
POWER DOWN ADC
TURN ON DRIVERS: Y+, X-
YES
NO
POWER UP ADC
IS TOUCH-SCREEN
SETTLING DONE?
Figure 22. Touch-Initiated X- , Y-, and Z- Coordinate Screen Scan
MAX1233/MAX1234
±15kV ESD-Pr
otected T
ouch-Scr
een
Contr
ollers Include DAC and Keypad Contr
oller
38
______________________________________________________________________________________
YES
SCREEN
TOUCH
ST
ART CLOCK
HOST WRITES
ADC CONTROL REGISTER
(PENSTS = ADSTS = 0)
NO
NO
YES
POWER UP ADC
YES
SET
PENIRQ LOW
ARE THERE
UNREAD SCAN
RESUL
TS?
NO
CONVERT X- COORDINA
TES
IS TOUCH-SCREEN
SETTLING DONE?
NO
IS DA
T
A
AVERAGING DONE?
STORE X- COORDINA
TES
IN X- REGISTER
YES
NO
POWER DOWN ADC
POWER UP ADC
TURN ON DRIVERS: X+, X-
CONVERT Y
- COORDINA
TES
IS TOUCH-SCREEN
SETTLING DONE?
YES
NO
IS DA
T
A
AVERAGING DONE?
IS PENSTS
BIT = 1?
SET BUSY LOW
TURN ON DRIVERS: Y+, Y
-
DONE
TURN OFF CLOCK
SET BUSY HIGH
STORE Y
- COORDINATES IN
Y
- REGISTER
RESET PENIRQ HIGH
HOST
-INITIA
TED
X- AND Y
- SCREEN SCAN
POWER DOWN ADC
GO TO
TOUCH-INITIA
TED
SCAN
(FIGURE 21)
YES
Figure 23. Host-Initiated X- and Y- Coordinate Screen Scan
MAX1233/MAX1234
±15kV ESD-Pr
otected T
ouch-Scr
een
Contr
ollers Include DAC and Keypad Contr
oller
______________________________________________________________________________________
39
YES
SCREEN
TOUCH
ST
ART CLOCK
HOST WRITES
ADC
CONTROL REGISTER
NO
NO
POWER UP ADC
YES
SET
PENIRQ LOW
ARE THERE
UNREAD SCAN
RESUL
TS?
NO
CONVERT X- COORDINA
TES
IS TOUCH-SCREEN
SETTLING DONE?
YES
NO
STORE X- COORDINA
TES
IN X- REGISTER
POWER DOWN ADC
IS DA
T
A
AVERAGING DONE?
TURN ON DRIVERS: Y+, X-
TURN ON DRIVERS: X+, X-
YES
NO
POWER UP ADC
CONVERT Y
- COORDINATES
IS TOUCH-SCREEN
SETTLING DONE?
YES
NO
STORE Y
- COORDINATES IN
Y
- REGISTER
POWER DOWN ADC
IS DA
T
A
AVERAGING DONE?
YES
NO
POWER UP ADC
CONVERT Z
1
- COORDINA
TES
IS TOUCH-SCREEN
SETTLING DONE?
YES
NO
IS DA
T
A
AVERAGING DONE?
IS PENSTS
BIT = 1?
SET BUSY LOW
TURN ON DRIVERS: Y+, Y
-
DONE
TURN OFF CLOCK
SET BUSY HIGH
STORE Z
1
- COORDINA
TES
IN Z
1
- REGISTER
YES
NO
IS DA
T
A
AVERAGING DONE?
CONVERT Z
2
-
COORDINA
TES
STORE Z
2
- COORDINA
TES
IIN Z
2
- REGISTER
RESET PENIRQ HIGH
HOST
-INITIA
TED
X-, Y
-, AND Z- SCREEN SCAN
POWER DOWN ADC
GO TO
TOUCH-INITIA
TED
SCAN
(FIGURE 22)
YES
Figure 24. Host-Initiated X-, Y-, and Z- Coordinate Screen Scan
P1-P3
P4-P6
P7-P9
P10-P12
P13-P15
P16-P18
P19-P21
P22-P24
P25-P27
P28-P30
P31-P33
P34-P36
P37-P39
P40-P42
P43-P44
MAX1233ETI+T
Mfr. #:
Buy MAX1233ETI+T
Manufacturer:
Maxim Integrated
Description:
Touch Screen Controllers 4Ch uWire QSPI/SPI Touch Interface
Lifecycle:
New from this manufacturer.
Delivery:
DHL
FedEx
Ups
TNT
EMS
Payment:
T/T
Paypal
Visa
MoneyGram
Western
Union
Products related to this Datasheet
MAX1234ETI+T
MAX1233ETI+T
MAX1234ETI+
MAX1233ETI+
MAX1234EGI+