HE1AN-W-DC9V-Y6

–1–
ASCTB101E 201603-T
Compact size,
1 Form A 35A/48A/90A
power relays
for solar inverter
HE RELAYS
PV Type
Protective construction: Flux-resistant
type
35A type
48A type 90A type
RoHS compliant
FEATURES
1. High capacity and compact size
High capacity control possible (35A/
48A/90A type)
35A/48A type: L: 33 × W: 38 ×
H: 36.3mm L: 1.299 × W: 1.496 ×
H: 1.429inch
90A type: L: 33 × W: 38 × H: 38.8mm
L: 1.299 × W: 1.496 × H: 1.528inch
Due to improved conduction efficiency,
wide terminal blades are used (for 48A
and 90A type)
2. Contact GAP
Compliant with European photovoltaic
standard VDE0126
Compliant with EN61810-1 2.5kW
surge breakdown voltage (between
contacts)
35A/48A type: 2.5mm .098inch
90A type: 3.0mm .118inch
3. Contributes to energy saving in
devices thanks to reduced coil hold
voltage
Coil hold voltage can be reduced down
40% of the nominal coil voltage
(ambient temperature 20°C 68°F)
This is equal to operating power of
approximately 310mW.
*Coil hold voltage is the coil voltage after 100ms
following application of the nominal coil voltage.
4. High insulation and 10,000V surge
breakdown voltage (between
contacts and coil)
TYPICAL APPLICATIONS
Inverter (Solar and industrial)
UPS
Stationary charging stand
(48A type)
HE PV Type
–2–
ASCTB101E 201603-T
ORDERING INFORMATION
TYPES
Standard packing: Carton: 25 pcs.; Case: 100 pcs.
*35A 6V,12V and 24V DC type: Certified by UL/C-UL (35A 9V type: Certified by UL/C-UL and VDE)
RATING
1. Coil data
Type Nominal coil voltage Contact arrangement Part No.
35A*
6V DC
1 Form A
HE1aN-P-DC6V-H18
9V DC HE1aN-P-DC9V-H18
12V DC HE1aN-P-DC12V-H18
24V DC HE1aN-P-DC24V-H18
48A
6V DC HE1aN-P-DC6V-Y5
9V DC HE1aN-P-DC9V-Y5
12V DC HE1aN-P-DC12V-Y5
24V DC HE1aN-P-DC24V-Y5
90A
6V DC HE1aN-W-DC6V-Y6
9V DC HE1aN-W-DC9V-Y6
12V DC HE1aN-W-DC12V-Y6
24V DC HE1aN-W-DC24V-Y6
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
(Initial)
Drop-out voltage
(at 20°C 68°F)
(Initial)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
6V DC
70%V or less of
nominal voltage
10%V or more of
nominal voltage
320mA 18.8Ω
1,920mW
110%V of
nominal voltage
9V DC 213mA 42.2Ω
12V DC 160mA 75.0Ω
24V DC 80mA 300.0Ω
Contact arrangement
1a: 1 Form A (Single side stable type)
Pick-up voltage
N: 70% of nominal voltage
HE 1a N DC
Terminals
P:
W:
PC board terminal type / Blade terminal type
Wide blade terminal type
Coil voltage (DC)
6, 9, 12, 24V
Type, contact material and switching capacity
Y5:
Y6:
H18:
PV type, AgNi type (1 Form A 48A)
PV type, AgNi type (1 Form A 90A)
PV type, AgSnO2 type (1 Form A 35A)
HE PV Type
–3–
ASCTB101E 201603-T
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. Coil hold voltage is the coil voltage after 100 ms following application of the nominal coil voltage.
*4. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*5. Release time will lengthen if a diode, etc., is connected in parallel to the coil. Be sure to verify operation under actual conditions.
Characteristics Item
Specifications
35A type 48A type 90A type
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6V DC 1A)
Max. 10 mΩ
(By voltage drop 5V DC 20A)
Contact material AgSnO
2 type AgNi type
Rating
Nominal switching capacity 35A 277V AC (Resistive load) 48 A 277V AC (Resistive load) 80A 277V AC (Resistive load)
Contact carring power 9,695VA (Resistive load) 13,296VA (Resistive load) 24,930VA (Resistive load)
Max. switching voltage 277V AC
Max. switching current 35A (AC) 48A (AC) 90A (AC)
Nominal operating power 1,920mW
Min. switching capacity
(Reference value)*
1
100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown
voltage (Initial)
Between open
contacts
2,000 Vrms for 1 min. (Detection current: 10mA)
Between contact
and coil
5,000 Vrms for 1 min. (Detection current: 10mA)
Surge breakdown voltage*
2
(Between contact and coil)
10,000 V (Initial)
Temperature rise
Max. 60°C 140°F (By resistive
method, contact carrying current:
35A, 100%V of nominal coil voltage
at 55°C 131°F.)
Max. 60°C 140°F (By resistive
method, contact carrying current:
48A, 100%V of nominal coil voltage
at 55°C 131°F.)
Max. 60°C 140°F (By resistive
method, contact carrying current:
90A, 100%V of nominal coil voltage
at 55°C 131°F.)
Max. 30°C 86°F (By resistive
method, contact carrying current:
35A, 60%V of nominal coil voltage at
85°C 185°F.)
Max. 30°C 86°F (By resistive
method, contact carrying current:
48A, 60%V of nominal coil voltage at
85°C 185°F.)
Max. 30°C 86°F (By resistive
method, contact carrying current:
90A, 60%V of nominal coil voltage at
85°C 185°F.)
Coil hold voltage*
3
40 to 100%V (Contact carrying
current: 35A, at 20°C 68°F),
50 to 100%V (Contact carrying
current: 35A, at 55°C 131°F),
50 to 60%V (Contact carrying
current: 35A, at 85°C 185°F)
40 to 100%V (Contact carrying
current: 48A, at 20°C 68°F),
50 to 100%V (Contact carrying
current: 48A, at 55°C 131°F),
50 to 60%V (Contact carrying
current: 48A, at 85°C 185°F)
40 to 100%V (Contact carrying
current: 90A, at 20°C 68°F),
50 to 60%V (Contact carrying
current: 90A, at 85°C 185°F)
Operate time (at 20°C 68°F) Max. 30 ms (nominal coil voltage, excluding contact bounce time)
Release time (at 20°C 68°F)*
5
Max. 10 ms (nominal coil voltage, excluding contact bounce time) (without diode)
Mechanical
characteristics
Shock
resistance
Functional 98 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10 μs.)
Destructive 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration
resistance
Functional 10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10 μs.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical Min. 10
7
(at 180 times/min.) Min. 1×10
6
(at 180 times/min.)
Electrical Resistive load
Min. 3×10
4
(35A 277V AC)
(ON : OFF = 1s : 9s, at 85°C 185°F)
Min. 3×10
4
(48A 277V AC)
(ON : OFF = 1s : 9s, at 85°C 185°F)
Min. 1×10
4
(80A 277V AC)
(ON : OFF = 1s : 9s, at 20°C 68°F)
Min. 1×10
3
(90A 250V AC)
(ON : OFF = 1s : 9s, at 85°C 185°F)
Conditions
Conditions for operation, transport
and storage*
4
Ambient temperature:
–50 to +55°C –58 to +131°F (When nominal coil voltage applied)
–50 to +85°C –58 to +185°F (When applied coil hold voltage is 50% to 60% of nominal coil voltage)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature);
Air pressure: 86 to 106 kPa
Max. operating speed 6 times/min. (at nominal switching capacity ON : OFF = 1s : 9s)
Unit weight Approx. 80 g 2.82 oz Approx. 85 g 3.00 oz

HE1AN-W-DC9V-Y6

Mfr. #:
Manufacturer:
Panasonic
Description:
HE PV 90A RELAY WITH 9VDC COIL
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union