Curtis Industries
A Division of Powers Holdings, Inc.
1-800-657-0853
Dimensions are in inches and millimeters
unless otherwise specified.
Values in parentheses are metric equivalents.
General Purpose
5
SINGLE PHASE FILTERS
L
I
N
E
L
O
A
D
B
D
A
E
C
.188 Dia.
(4,77) 2 Holes
.250 Q.C.
(6.4)
Amps A B C D E
1A
2.500
(63,5)
1.750
(44,5)
.625
(15,8)
2.125
(53,9)
.875
(22,2)
3A
2.500
(63,5)
1.750
(44,5)
.750
(19,1)
2.125
(53,9)
1.250
(31,8)
6A
2.500
(63,5)
1.750
(44,5)
.750
(19,1)
2.125
(53,9)
1.250
(31,8)
10A
2.500
(63,5)
1.750
(44,5)
1.125
(28,5)
2.125
(53,9)
1.250
(31,8)
F1100BB/FB1150BB
(1, 3, 6 and 10Amp) Dimensions
L
I
N
E
L
O
A
D
.188 Dia.
(4,77) 2 Holes
D
A
B
E
4.000
(101,6)
Min.
C
No. 18 Gauge Wire
.250±.062
(6,35) Typ.
F1100DD/F1150DD
(20Amp Only) Dimensions
L
I
N
E
L
O
A
D
.188 Dia.
(4,77) 2 Holes
2.000
(50,8)
2.000
(50,8)
.625
(15,8)
.625
(15,8)
1.125
(25,5)
2.760
(70,6)
2.375
(60,3)
(5) No. 8-32
Studs
Amps A B C D E
1A
2.500
(63,5)
1.750
(44,5)
.625
(15,8)
2.125
(53,9)
1.425
(362)
3A
2.500
(63,5)
1.750
(44,5)
.750
(19,1)
2.125
(53,9)
1.8
(45,8)
6A
2.500
(63,5)
1.750
(44,5)
.750
(19,1)
2.125
(53,9)
1.8
(45,8)
10A
2.500
(63,5)
1.750
(44,5)
1.125
(28,5)
2.125
(53,9)
1.8
(45,8)
20A
2.760
(70,6)
2.000
(60,8)
1.125
(28,5)
2.375
(60,3)
2.550
(64,8)
F1100AA/F1150AA
(1, 3, 6, 10 and 20Amp) Dimensions
Specifications:
Rated Voltage: 250VAC Maximum - 50/60 Hz
Rated Current: 115VAC 250VAC
1A 1A
2A 1.5A
3A 2.5A
6A 4A
10A 6A
20A 10A
30A 15A
Current Overload: 6X for 8 seconds
Hi-Pot Test (1 min): F1100/F1150 F1199
Line to Ground: 1500VAC 1500VAC
Line to Line: 1768VDC 1450VDC
Insulation Resistance: 9 x 10
9
Ω at 100VDC
Ambient Temperature: 40°C Max. at rated current
Humidity Range: 0% to 95% R.H.
Termination:
A: QC – Quick Connect D: Screw
B: Wire P: PCB Mount
Maximum Leakage Current:
Each Line to Ground F1100 F1150 F1199
115VAC, 60Hz: 0.40mA 0.25mA 0.25mA
250VAC, 50Hz: .75mA 0.40mA 0.45mA
Agency Approvals:
F1100 F1100 F1100
F1150 F1500
Except 20Amp
F1150
F1199 F1199 F1199 F1199