FST16060

Curtis Industries
A Division of Powers Holdings, Inc.
www.curtisind.com
Specications subject to change.
Dimensions are shown for
reference purposes only.
20
SINGLE PHASE FILTERS
NOTE: Other combinations of terminals may be specied on special order.
Features:
• T Section, Dual Coil Design – High Insertion Loss for
Switching Power Supply Emissions
• Low-Leakage Current Design
• Space-Efficient with Integral IEC Connector and
Compact Case in Current Ratings up to 10Amps
• Available in Fused IEC Connector and PC Mounted
Versions
F1600CX Simplied Schematic
F1600FA Simplied Schematic
Nominal
Current
Rating
Part
Number
Termination
Line/Load
MINIMUM INSERTION LOSS - dB (50 ohm Circuit)
MODE
Frequency - MHz
.15 .50 1.0 5.0 10 30
3A
F1600CA03
F1600CP03
F1600FA03
F1600CB03
IEC/QC
IEC/PC
Fused IEC/QC
IEC/Wire
Common
Differential
52
40
65
50
65
60
65
65
65
65
65
50
6A
F1600CA06
F1600CP06
F1600FA06
F1600CB06
IEC/QC
IEC/PC
Fused IEC/QC
IEC/Wire
Common
Differential
45
30
65
45
65
55
65
50
65
50
59
50
10A
F1600CA10
F1600CB10
IEC/QC
IEC/Wire
Common
Differential
50
23
65
45
65
55
65
50
65
50
54
50
Specications:
Rated Voltage: 250VAC Maximum - 50/60 Hz
Rated Current: 115VAC 250VAC
3A 1.5A
6A 3A
10A 6A
Current Overload: 6X for 8 seconds
Hi-Pot Test (1 min):
Line to Ground 1500VAC
Line to Line 1768VDC
Insulation Resistance: 9 x 10
9
Ω at 100VDC
Ambient Temperature: 40°C Max. at rated current
Humidity Range: 0% to 95% R.H.
Termination:
A: QC – Quick Connect
B: Wire
C: IEC Receptacle
P: PC – P.C. Board
Maximum Leakage Current:
Each Line to Ground F1600
115VAC, 60Hz: 0.25mA
250VAC, 50Hz: 0.40mA
Agency Approvals:
F1600 RFI Filters
LINE
LOAD
L
G
N
L
N
LOAD
L
N
LINE
L
G
N
High Performance
Curtis Industries
A Division of Powers Holdings, Inc.
1-800-657-0853
Dimensions are in inches and millimeters
unless otherwise specied.
Values in parentheses are metric equivalents.
21
SINGLE PHASE FILTERS
F1600CA (3, 6 and 10Amp) Dimensions F1600CB (3, 6 and 10Amp) Dimensions
F1600FA
(3 and 6Amp)
Dimensions
Refer to Page 40
for Standard
Mounting Cutouts
E
(2) No. 6-32 UNC2B
B
AD
C
.250 QC
L
I
N
E
L
O
A
D
F1600CP
(3 and 6Amp)
Dimensions
Refer to Page 40
for Standard
Mounting Cutouts
Amps A B C D E
3A
2.500
(63,5)
2.000
(50,8)
1.500
(38,2)
.550
(14,0)
.565
(14,3)
6A
2.500
(63,5)
2.000
(50,8)
1.500
(38,2)
.550
(14,0)
.565
(14,3)
10A
3.750
(95,2)
2.250
(57,2)
1.750
(44,5)
.550
(14,0)
.640
(16,3)
2.00
(50,8)
B
2.500
(63,5)
2,500
(63.5)
1.500
(38.2)
1.500
(38,2)
(2) No. 6-32
UNC2B
.935
(19,1)
.500
(12,7)
1.540
(39,1)
.210
(53,3)
L
I
N
E
L
O
A
D
L
I
N
E
L
O
A
D
.752
(19,1)
(2) No. 6-32 UNC2B
(1) 5mm x 20mm FUSE
(not included)
.550
(14.0)
.250 QC
(6,4)
High Performance
Refer to Page 40
for Standard
Mounting Cutouts
Curtis Industries
A Division of Powers Holdings, Inc.
www.curtisind.com
Specications subject to change.
Dimensions are shown for
reference purposes only.
40
SINGLE PHASE FILTERS
Standard Mounting Cutouts
F1200CA, F1300CA, F1400CA,
F1500CA, F1600CA, F1700CA
F1500FA, F1600FA,
1.145
(29,08)
1.417
(36,0)
1.275
(32,39)
.09 R
(2,29)
.638
(16,21)
.140 Dia.
(3,55)
2 Holes
1.20
(30.5)
.90
(22,9)
1.575
(40,0)
.187
(4,75)
.450
(11,43)
.234
(5,94)
.140 Dia.
(3,55)
2 Holes
F1300CP, F1600CP
.062 Hole Dia.
(1,57)
5 Holes
1.500
(38,1)
.600
(15,2)
.700
(17,8)
1.400
(35,6)
N
L
F5500/5600/5700 SERIES
.140 Dia.
(3,55)
2 Holes
.234 R.
(5,94)
(Typ.)
1.575
(40,01)
1.20
(30,48)
.90
(22,8)
for mounting
from back side
SERIES
PE = Power Entry
PM = Medical
Power Entry
LOAD
TERMINATION
A = Quick Connects
B = Wire Leads
D = Screw Terminals
(20 & 30 amp only)
P = Printed Circuit Pins
S = Solder Tab
LINE TERMINATION
A = Quick Connects
B = Wire Leads
C = IEC Connector
D = Screw Terminals
(20 & 30 amp only)
F = Fused IEC
P = Printed Circuit Pins
W = Dual Fused IEC
J = Switched IEC
How to Order
The Curtis part numbering system is made up of four
elements. Each element denotes a specic requirement
(mechanical or electrical) which, when properly
sequenced, fully identies the required catalog lter. As
shown, the rst ve alpha/numeric characters denote
the series type; the sixth character (alpha) denotes the
type of line termination; the seventh character (alpha)
denotes the type of load termination; the last two
characters (numeric) denote the current rating.
Compose your part number as follows: Select the series
required, add two alpha character for the line and load
termination, followed by two numeric characters for
the required current rating. For example, F1100AB06
completely identies an F1100 series lter with quick
connects on line side and wire leads on load side, with
a 6-amp rating.
F1100 X X X
CURRENT
RATING
01 = 1 Amp
03 = 3 Amps
06 = 6 Amps
10 = 10 Amps
15 = 15 Amps
20 = 20 Amps
30 = 30 Amps

FST16060

Mfr. #:
Manufacturer:
GeneSiC Semiconductor
Description:
Schottky Diodes & Rectifiers 60V 160A Schottky Recovery
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet