7
FIGURE 6. HB TO VSS OPERATING CURRENT vs
FREQUENCY
FIGURE 7. HIGH LEVEL OUTPUT VOLTAGE vs TEMPERATURE
FIGURE 8. LOW LEVEL OUTPUT VOLTAGE vs
TEMPERATURE
FIGURE 9. UNDERVOLTAGE LOCKOUT THRESHOLD vs
TEMPERATURE
FIGURE 10. UNDERVOLTAGE LOCKOUT HYSTERESIS vs
TEMPERATURE
FIGURE 11. PROPAGATION DELAYS vs TEMPERATURE
Typical Performance Curves (Continued)
T = -40°C
T = 125°C
T = 25°C
T = 150°C
10
1
0.1
0.01
I
HBSO
(mA)
10 100 1000
FREQUENCY (kHz)
TEMPERATURE (°C)
V
OHL
, V
OHH
(mV)
500
400
300
200
100
-50 0 50 100
150
V
HB
= V
DD
= 9V
V
HB
= V
DD
= 12V
V
HB
= V
DD
= 14V
TEMPERATURE (°C)
V
OLL
, V
OLH
(mV)
500
400
300
200
100
-50 0 50 100 150
V
HB
= V
DD
= 9V
V
HB
= V
DD
= 12V
V
HB
= V
DD
= 14V
TEMPERATURE (°C)
-50 0 50 100 150
7.6
7.4
7.2
7.0
6.8
6.6
V
DDR
V
HBR
V
HBR
, V
DDR
(V)
TEMPERATURE (°C)
-50 0 50 100 150
0.54
0.5
0.46
0.42
0.38
0.3
V
DDH
V
HBH
V
HBH
, V
DDH
(mV)
0.34
t
HPHL
t
HPLH
t
LPHL
t
LPLH
TEMPERATURE (°C)
-50 0 50 100 150
30
25
20
15
t
LPLH
, t
LPHL
, t
HPLH
, t
HPHL
(ns)
HIP2101
8
FIGURE 12. PEAK PULLUP CURRENT vs OUTPUT VOLTAGE
FIGURE 13. PEAK PULLDOWN CURRENT vs OUTPUT
VOLTAGE
FIGURE 14. BOOTSTRAP DIODE I-V CHARACTERISTICS FIGURE 15. QUIESCENT CURRENT vs VOLTAGE
FIGURE 16. VHS VOLTAGE vs V
DD
VOLTAGE
Typical Performance Curves (Continued)
6
2.0
I
HO
, I
LO
(A)
12108420
2.5
1.5
1.0
0.5
0
V
HO
, V
LO
(V)
6
2.0
I
LO
, I
HO
(A)
12108420
2.5
1.5
1.0
0.5
0
V
LO
, V
HO
(V)
0.8
1
0.1
0.01
0.001
110
-4
110
-5
110-6
0.70.60.50.40.3
FORWARD VOLTAGE (V)
FORWARD CURRENT (A)
V
DD
, V
HB
(V)
0 5 10 15
60
50
40
0
I
DD
, I
HB
(A)
30
20
10
I
DD
vs V
DD
I
HB
vs V
HB
120
100
80
60
40
20
0
14 15 1612
VHS TO V
SS
VOLTAGE (V)
V
DD
TO V
SS
VOLTAGE (V)
HIP2101
9
About Intersil
Intersil Corporation is a leading provider of innovative power management and precision analog solutions. The company's products
address some of the largest markets within the industrial and infrastructure, mobile computing and high-end consumer markets.
For the most updated datasheet, application notes, related documentation and related parts, please see the respective product
information page found at www.intersil.com.
You may report errors or suggestions for improving this datasheet by visiting www.intersil.com/ask.
Reliability reports are also available from our website at www.intersil.com/support.
Revision History
The revision history provided is for informational purposes only and is believed to be accurate, but not warranted. Please go to the web to make
sure that you have the latest revision.
DATE REVISION CHANGE
November 12, 2015 FN9025.9 - Updated Ordering Information Table on page 1.
- Added Revision History.
- Added About Intersil Verbiage.
- Updated POD L12.4X4A to latest revision changes are as follow:
Updated to new POD format by removing table listing dimensions and moving dimensions onto
drawing.
Added Typical Recommended Land Pattern.
Bottom View changed "3.2 REF" TO "2.5 REF"
Typical Recommended Land Pattern changed "3.80" to "3.75"
From: Tiebar shown (if present) is a non-functional feature.
To: Tiebar shown (if present) is a non-functional feature and may be located on any of the 4 sides (or
ends).
- Updated POD M8.15 to latest revision changes are as follow:
Updated to new POD format by removing table and moving dimensions onto drawing and adding land
pattern.
Changed in Typical Recommended Land Pattern the following:
2.41(0.095) to 2.20(0.087)
0.76 (0.030) to 0.60(0.023)
0.200 to 5.20(0.205)
Changed Note 1 "1982" to "1994"
- Updated POD M8.15C to most current version.
Removed "u" symbol from drawing (overlaps the "a" on Side View).
HIP2101

HIP2101IBZT

Mfr. #:
Manufacturer:
Renesas / Intersil
Description:
Gate Drivers VER 100V HALFBRDG DR VR
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union