SPECIFICATION
480W Single Output Switching Power Supply
HEP-480 series
File Name:HEP-480-SPEC 2018-03-30
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
℃
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
Note.5
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.4
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
Note.7
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
500ms, 80ms 115VAC/230VAC
16ms 115VAC/230VAC
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF 0.98/115VAC, PF 0.97/230VAC, PF 0.95/277VAC at full load≧≧≧
<0.75mA / 277VAC
105 ~ 125%
Constant current limiting, recovers automatically after fault condition is removed
Compliance to ,EN55032 (CISPR32) Class B, EN61000-3-2,-3 EAC TP TC 020
Compliance to , industry level (surge 6KV), criteria A,
EN61000-4-2,3,4,5,6,8,11, EN55024 light EAC TP TC 020
-55 ~ +65 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-60 ~ +80 , 10 ~ 95% RH non-condensing℃
±℃ ℃
0.02%/ (0 ~ 60 )
20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes
89.8K hrs min. MIL-HDBK-217F (25 )
℃
262*125*43.8mm (L*W*H)
Shut down output voltage, re-power on to recover
Shut down voltage,output re-power on to recover
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
27 ~ 33V 40 ~ 50V 53 ~ 63V 60 ~ 70V
94% 95% 94.5% 95%
±1.0% ±1.0% ±1.0% ±1.0%
10 ~ 20A 6.6 ~ 13.3A 5 ~ 10A 4.4 ~ 8.9A
±0.5% ±0.5% ±0.5% ±0.5%
±0.5% ±0.5% ±0.5% ±0.5%
24V 36V 48V 54V
HEP-480-24 HEP-480-36 HEP-480-48 HEP-480-54
20A 13.3A 10A 8.9A
480W 478.8W 480W 480.6W
200mVp-p 250mVp-p 250mVp-p 350mVp-p
Adjusted for A-type only (via built-in potentiometer)
20.4 ~ 25.2V 30.6 ~ 37.8V 40.8 ~ 50.4V 45.9 ~ 56.7V
EMC IMMUNITY
EMC EMISSION
COLD START 35A at 230VAC
PACKING
2.8Kg;4pcs/11.5Kg/0.55CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the setup time.
5. Derating may be needed under low input voltages. Please refer to the STATIC CHARACTERISTICS for more details.
6. The power supply shall be regarded as one component of the final system. The EMC performance will be affected by the complete system installation
and/or configuration, the final system manufacturers must re-verify overall EMC directive with the complete installation and/or configuration.
7. The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month.
8. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
AC CURRENT (Typ.) 5A / 115VAC 2.45A / 230VAC 2A/277VAC
UL60950-1 EAC TP TC 004, IP65 (or IP68 for HEP-480 Blank-Type), approved ; design refer to TUV EN60950-1
Adjusted for A-type only (via built-in potentiometer)