SPECIFICATION
150W Single Output Switching Power Supply
LRS-150 series
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
Note.4
LOAD REGULATION
Note.5
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
AC CURRENT (Typ.)
500ms, 30ms/230VAC 500ms,30ms/115VAC at full load
40ms/230VAC 35ms/115VAC at full load
85 ~ 132VAC / 170 ~ 264VAC by switch 240 ~ 370VDC(switch on 230VAC)
47 ~ 63Hz
3A/115VAC 1.7A/230VAC
COLD STAR 60A/230VAC
<0.75mA / 240VAC
110 ~ 140% rated output power
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
-30 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
601K hrs min. MIL-HDBK-217F (25 )℃
0.48Kg ; 30pcs/15.4Kg/0.75CUFT
159*97*30mm (L*W*H)
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE Note.3
PROTECTION
ENVIRONMENT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SAFETY STANDARDS
UL60950-1, TUV EN60950-1, EN60335-1, EN61558-1 2 16 .1, BSMI CNS14336-1,/- - ,CCC GB4943
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
Compliance to EN55032 (CISPR32) Class B, EN55014, EN61000-3-2 Class A( 75% Load),EN61000-3-3,≤
GB/T 9254, BSMI CNS13438, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020
SAFETY &
EMC
(Note 7)
EMC IMMUNITY
EMC EMISSION
OVER TEMPERATURE
87.5%
88.5%
89%
90%
12V
15V
24V
48V
12.5A
10A
6.5A
3.3A
0 ~ 12.5A
0 ~ 10A
0 ~ 6.5A
0 ~ 3.3A
150W
150W
156W
158.4W
150mVp-p
150mVp-p
200mVp-p
200mVp-p
±1.0%
±1.0%
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
89%
36V
4.3A
0 ~ 4.3A
154.8W
200mVp-p
±1.0%
±0.5%
±0.5%
13.8 ~ 16.2V 18.75 ~ 21.75V 28.8 ~ 33.6V 41.4 ~ 48.6V 55.2 ~ 64.8V
10.2 ~ 13.8V
13.5 ~ 18V
21.6 ~ 28.8V
43.2 ~ 52.8V
32.4 ~ 39.6V
LRS-150-12 LRS-150-15 LRS-150-24 LRS-150-36 LRS-150-48
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up
time.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by
mounting the unit on a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets360 360
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
8. The ambient temperature derating of 5 /1000m is needed for operating altitude greater than 2000m (6500ft).℃
File Name:LRS-150-SPEC 2018-02-27
OVER VOLTAGE CATEGORY
Ⅲ; Compliance to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters
EAC TP TC 004, AS/NZS 60950.1(by CB) approved