CST206-1A

Current Sense Transformers
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: June 8, 2016
G
A
B
D
F
H
C
L
E
C
CST206-1A
Description:
Designed for switching power supply applications, Triad current sense
transformers are used to detect the current passing through a conductor.
These transformers are very reliable and operate over the frequency range of
20 kHz-200 kHz.
Electrical Specifications (@25C)
ET VµSEC
REF 20kHz
Turns
Count
Min.
Ind. mH
DCR Max. Ω Pri. Amps
2000 100 14.0 .580 110.0 RMS
Safety:
These current sense transformers are constructed of UL rated 130°C materials.
Dimensions:
A
Min
B
Max
C
Ref
D
Ref
E
Ref
F
Max
G
Max
H
Dia. Pins
.360 1.225 .700 .127 .500 .400 1.075 .045
Units: In inches
Technical Notes:
1. Derate ET product by 32% for 50 kHz, 52% for 100Hz and 50% for
unidirectional operation.
2. Rated primary current renders approximately 40°C temp. rise.
3. Maximum recommended terminating resistance of 1 ohm per turn.
4. Primary is inserted through hole in casting.
ST
FN
PIN 1
TEST CONDUCTOR
ARROW
POLARITY DETAIL TOP VIEW
1. START OF TEST CONDUCTOR TO HAVE
THE SAME POLARITY AS PIN 1
2. DECAL ARROW ON CASE TO INDICATE
POLARITY
1
RoHS Compliance: As of manufacturing date February 2005, all standard products meet the
requirements of 2011/65/EU, known as the RoHS initiative.
*Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics
website for the most current version. For soldering and washing information please see
http://www.triadmagnetics.com/faq.html

CST206-1A

Mfr. #:
Manufacturer:
Triad Magnetics
Description:
Current Transformer Sensors Current Transformers 14mH 110A SENSING
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union