NFS40-7610J

313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Embedded Power for
Business-Critical Continuity
NFS40 Series
SIngle and
triple output
Special Features
• 5.0 x 3.0 x 1.2 inch package
(1U applications)
• Industry standard package
• Overvoltage and
short circuit protection
• 40 W with free air convection
• 50 W with 20 CFM forced air
• EN55022, EN55011
conducted noise level B
• UL, VDE and CSA
safety approvals
• Available RoHS compliant
• 2 year warranty
Total Power: 40 - 50W
Input Voltage: 85 - 264 Vac
120 - 370 Vdc
# of Outputs: Single, triple
Safety
VDE0805/EN60950/
IEC950/IEC1010
File No. 10401-3336-0044
License No. 2559
UL1950 File No. E136005
CSA C22.2 No. 950
File No. LR41062C
Rev.02.01.10_65
NFS40 Series
1 of 4
Electrical Specications
Input
Voltage adjustability:
+5 V output on triples
Vout on singles
± 5.0%
± 5.0%
Line regulation:
LL to HL, FL
Main output
Auxiliary outputs
± 0.2%
± 1.0%
Load regulation:
FL to NL
Main output
Auxiliary outputs
± 2.0%
± 5.0%
Transient response:
+5 V (1.5 - 3 A) ± 120 mV max. dev.
500 µs recovery
Temperature coefcient:
All outputs ± 0.02%/°C
Overvoltage protection:
+5 V output S3.15 A, 250 Vac In live and neutral
Output power limit:
Primary power limited 90 W input power limit
Short circuit protection:
Single outputs
Multiple outputs
Continuous
Short term
Output
Input voltage range:
Universal input 85 - 264 Vac
120 - 370 Vdc
Input frequency range:
47-440 Hz
Max. input surge current:
132 Vac, cold start
264 Vac, cold star
12 A max.
24 A max.
Safety ground leakage current:
110 Vac, 60 Hz
230 Vac, 50 Hz
0.13 mA, max.
0.32 mA, max.
Rev.02.01.10_65
NFS40 Series
2 of 4
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
All specications are typical at nominal input, full load at 25 °C unless otherwise stated
Specications
Environmental Specications
Thermal performance: Operating 0° C to +70 °C
(See notes 8, 10) Non-operating -40 °C to +85 °C
50 °C ambient temp.,
convection cooled
40 W
Forced air cooling 50 W @ 20 CFM
+50 °C to +70 °C ambient Derate linearly to 50% load
Peak (60 seconds) 60W
Relative humidity: Non-condensing 5 to 80% RH
Altitude: Operating 10,000 feet max.
Non-operating 40,000 feet max.
Vibration (See Note 11): 5-500 Hz 2.4 G rms peak
EMC Charateristics
(11, 12)
Conducted emissions:
EN55022, FCC part 15 Level B
Radiated emissions:
EN55022 Level A
ESD air:
EN61000-4-2, level 3 Perf. criteria 1
ESD contact:
EN61000-4-2, level 4 Perf. criteria 1
Surge:
EN61000-4-2, level 3 Perf. criteria 1
Fast transients:
EN61000-4-4, level 3 Perf. criteria 1
Radiated immunity:
EN61000-4-3, level 3 Perf. criteria 2
Conducted immunity:
EN61000-4-6, level 3 Perf. criteria 2
General Specications
Hold-up time:
110 Vac, 40 W
230 Vac, 40 W
14 ms
110 ms
Efciency:
70% typical
Isolation voltage:
Input/output
Input/chassis
3000 Vac
1500 Vac
Switching frequency:
Variable
Approvals and standards: (see
Notes 9, 13)
VDE0805, EN60950, IEC950, IEC1010,
UL1950, CSA C22.2 No. 950
Weight:
280 g (9.88 oz)
MTBF demonstrated:
MIL-HDBK-217E 170,000 hours
Rev.02.01.10_65
NFS40 Series
3 of 4
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Notes
1 Natural convection cooled, 40 W maximum.
2 Peak output current lasting less than 30 seconds with duty cycle less than 10%.
During peak loading, outputs may go outside of total regulation limits. Peak
total power must not exceed 60 W.
3 Forced air, 20 CFM at 1 atmosphere, 50 W maximum.
4 Figure is peak-to-peak. Output noise is measured across a 50 MHz bandwidth
using a 12 inch twisted pair, terminated with a 47 µF capacitor.
5 Total regulation is dened as the static output regulation at 25 °C, including
initial tolerance, line voltage within stated limits, load currents within stated
limits, and output voltages adjusted to their factory settings. Also, 0.25<I(A)/
I(B)<5.0 to maintain stated regulation. This does not apply to the NFS40-7628J
power supply as it has regulated auxiliary outputs.
6 A minimum load of 0.5 A is required on the +5 V output to obtain full current
from the negative output.
7 The NFS40 offers the possibility of power sharing between outputs. Consult
factory for details.
8 Derating curve is application specic for ambient temperatures >50 °C, for
optimum reliability no part of the heatsink should exceed 110
o
C and no
semiconductor case temperature should exceed 115
o
C.
9 A 4 W minimum load is recommended to achieve the design MTBF.
10 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
11 Three orthogonal axes, sweep at 1 octave/minute, 5 minute dwell at four major
resonances.
12 The NFS40-7628J has separately linear regulated +12 V and -12 V outputs. The
loading conditions in Notes 5 and 6 do not apply.
13 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
14 The ‘J’ sufx indicates that these parts are Pb-free (RoHS 6/6) compliant.
15 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number
search tool at http://www.PowerConversion.com to nd a suitable alternative.
Ordering Information
Output
Voltage
Output Currents Ripple
(4)
Total
Regulation
(5)
Model Numbers
(13, 14, F)
Max
(1)
Peak
(2)
Fan
(3)
+5.1 V (A) 3 A 7 A 5 A 50 mV ± 2.0% NFS40-7608J
(5,6)
+12 V (B) 2 A 3 A 2 A 120 mV ± 5.0%
–12 V (C) 0.35 A 1 A 0.5 A 120 mV ± 5.0%
+5.1 V (A) 4 A 7 A 5 A 50 mV ± 2.0% NFS40-7628J
(12)
+12 V (B) 0.35 A 1 A 0.5 A 120 mV ± 5.0%
-12 V (C) 0.35 A 1 A 0.5 A 120 mV + 5.0%
+5.1 V (A) 3 A 7 A 5 A 50 mV ± 2.0% NFS40-7607J
(5,6)
+12 V (B) 2 A 3 A 2 A 120 mV ± 5.0%
-5.0 V (C) 0.35 A 1 A 0.5 A 50 mV ± 5.0%
+5.1 V (A) 3 A 7 A 5 A 50 mV ± 2.0% NFS40-7610J
(5,6)
+15 V (B) 2 A 2.5 A 2 A 150 mV ± 10.0%/-3.0%
–15 V (C) 0.35 A 1 A 0.5 A 150 mV ± 5.0%
3.3 V 6 A 12 A 8 A 100 mV ± 2.0% NFS40-76S3J
+5.1 V 6 A 12 A 8 A 100 mV ± 2.0% NFS40-7605J
+12.0 V 3.3 A 5 A 4 A 120 mV ± 2.0% NFS40-7612J
+15.0 V 2.6 A 4 A 3.3 A 150 mV ± 2.0% NFS40-7615J
+24.0 V 1.6 A 2.5 A 2 A 240 mV ± 2.0% NFS40-7624J
Pin Connections
J1 -7608J, -7628J -7607J -7610J SINGLES
Pin 1 AC Live AC Live AC Live AC Line
Pin 2 AC Neutral AC Neutral AC Neutral AC Neutral
J2
Pin 1 +12 V +12 V +15 V +Vout
Pin 2 +5.1 V +5.1 V +5.1 V +Vout
Pin 3 +5.1 V +5.1 V +5.1 V +Vout
Pin 4 Return Return Return Return
Pin 5 Return Return Return Return
Pin 6 -12 V -5 V -15 V Return
P1
(c)
Pin 1 Safety Ground
DERATING CURVE
Output Power (Watts)
0C 10C 20C 30C 40C 50C 60C 70C
20W
40W
50W
20 CFM FORCED AIR COOLING
25W
NATURAL
CONVECTION
COOLING

NFS40-7610J

Mfr. #:
Manufacturer:
Description:
Switching Power Supplies 40W +5.1 +15 -15 OUT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: