B72220S3151K101

Leaded Varistors B72220S3151K101
SuperioR Series SIOV-S20K150E3
PPD VAR PD 2017-10-13
Please read Cautions and warnings and Page 7 of 11
Important notes at the end of this document.
Characteristics Test Methods/Description Specifications
Resistance to
soldering heat
IEC 60068-2-20, test Tb, method 1A, 260 °C, 10 s:
Each lead shall be dipped into a solder bath having
a temperature of 260 ±5 °C to a point 2.0 to 2.5 mm
from the body of the unit, be held there for 10 ±1 s
and then be stored at room temperature and normal
humidity for 1 to 2 hours. The change of V
v
shall be
measured and the part shall be visually examined.
|V/V (1 mA)| 5%
No visible damage
Bump IEC 60068-2-29, test Eb
Pulse duration: 6 ms
Max. acceleration: 400m/s
2
Number of bumps: 4000
Pulse: half sine
|V/V (1 mA)| 5%
No visible damage
Fire hazard IEC 60695-11-5 (needle flame test)
Severity: vertical 10 s
5 s max.
Electric strength IEC 61051-1, test 4.9.2
Metal balls method, 2500 V
RMS
, 60 s
The varistor is placed in a container holding 1.6 ±0.2
mm diameter metal balls such that only the
terminations of the varistor are protruding.
The specified voltage shall be applied between both
terminals of the specimen connected together and
the electrode inserted between the metal balls.
No breakdown
Leaded Varistors B72220S3151K101
SuperioR Series SIOV-S20K150E3
PPD VAR PD 2017-10-13
Please read Cautions and warnings and Page 8 of 11
Important notes at the end of this document.
Reliability Data Environmental
Characteristics Test Methods/Description Specifications
Endurance at upper
category temperature
1000 h at UCT
After having continuously applied the maximum
allowable voltage at UCT ±2 °C for 1000 h, the
specimen shall be stored at room temperature and
normal humidity for 1 to 2 h.
Thereafter, the change of V
v
shall be measured.
|V/V (1 mA)| 10%
Damp heat, steady
state
IEC 60068-2-78, test Ca
The specimen shall be subjected to 40 ±2 °C, 90 to
95 % r.H. for 56 days without load / with 10% of the
maximum continuous DC operating voltage V
DC
.
Then stored at room temperature and normal
humidity for 1 to 2 h.
Thereafter, the change of V
v
shall be measured.
Thereafter, insulation resistance R
ins
shall be
measured at V = 500 V (insulated varistors only).
|V/V (1 mA)| 10%
R
ins
100 M
Climatic sequence
The specimen shall be subjected to:
a) IEC 60068-2-2, test Ba, dry heat at UCT, 16 h
b) IEC 60068-2-30, test Db, damp heat, 1st cycle:
55 °C, 93% r.H., 24 h
c) IEC 60068-2-1, test Aa, cold, LCT, 2 h
d) IEC 60068-2-30, test Db, damp heat, additional 5
cycles: 55 °C/25 °C, 93% r.H., 24 h/cycle.
Then the specimen shall be stored at room
temperature and normal humidity for 1 to 2 h.
Thereafter, the change of V
v
shall be measured.
Thereafter, insulation resistance R
ins
shall be
measured at V = 500 V.
|V/V (1 mA)| 10%
R
ins
100 M
Rapid change of
temperature
-40°C to 125°C, dwell time 10 min, 1000 cycles
|V/V (1 mA)| 5%
No visible damage
Note:
UCT = Upper category temperature
LCT = Lower category temperature
R
ins
= Insulation resistance
Leaded Varistors B72220S3151K101
SuperioR Series SIOV-S20K150E3
PPD VAR PD 2017-10-13
Please read Cautions and warnings and Page 9 of 11
Important notes at the end of this document.
Cautions and warnings
General
1. EPCOS metal oxide varistors (SIOVs) are designed for specific applications and should not be used for
purposes not identified in our specifications, application notes and data books unless otherwise agreed with
EPCOS during the design-in-phase.
2. Ensure suitability of SIOVs through reliability testing during the design-in phase. The SIOVs should be
evaluated taking into consideration worst-case conditions.
3. For applications of SIOVs in line-to ground circuits based on various international and local standards there
are restrictions existing or additional safety measures required.
Storage
1. Store SIOVs only in original packaging. Do not open the package before storage.
2. Storage conditions in original packaging:
Storage temperature: -25 °C … +45 °C
Relative humidity: <75% annual average,
<95% on maximum 30 days a year.
Dew precipitation: Is to be avoided.
3. Avoid contamination of SIOVs surface during storage, handling and processing.
4. Avoid storage of SIOVs in harmful environments which can affect the function during long-term operation
(examples given under operation precautions).
5. The SIOV type series should be soldered after shipment from EPCOS within the time specified.
SIOV-S, -Q, -SNF, -LS 24 months.
ETFV and SFS types 12 months.
Handling
1. SIOVs must not be dropped.
2. Components must not be touched with bare hands. Gloves are recommended.
3. Avoid contamination of the surface of SIOV electrodes during handling, be careful of the sharp