V
O
PULSE
GEN.
Z = 50 Ω
t = 5 ns
O
r
I MONITOR
F
I
F
0.1µF
L
R
C
L
= 1.5 µF
R
M
0
t
PHL
t
PLH
O
V
F
OL
V
1.5 V
+5 V
1
2
3
4
8
7
6
5
1.5 V
5 V
10% DUTY CYCLE
1/f < 100 µS
O
V
5 V
OL
V
O
V
0 V
10%
90% 90%
10%
SWITCH AT A: I = 0 mA
F
SWITCH AT B: I = 16 mA
F
CM
V
t
r
t
f
7
1
2
3
4
5
6
8
V
O
0.1 µF
L
R
+5 V
PULSE GEN.
V
CM
+
-
V
I
F
A
B
FF
Figure 12. Test circuit for transient immunity and typical waveforms
Figure 11. Switching test circuit
For product information and a complete list of distributors, please go to our website: www.avagotech.com
Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies in the United States and other countries.
Data subject to change. Copyright © 2005-2014 Avago Technologies. All rights reserved. Obsoletes AV01-0550EN
AV02-0171EN - July 14, 2014
Figure 10. Frequency response
HCNW135/6
HCNW135/6
0.1 1.0 10 100
-20
-15
-10
-5
0
+5
T
A
= 25
°
C
f - FREQUENCY - MHz
6N135/6, HCPL-0500/1, HCPL-2502
7
1
2
3
4
5
6
8
+12 V
0.1 µF
V
FF
47 µF
51
Ω
2.1 K
Ω
100
Ω
1 K
Ω
1N4150
22
Ω
R
T
Q
1
TRIM FOR
UNITY GAIN
1.2 K
Ω
15 K
Ω
9.1 K
Ω
0.1 µF
100
Ω
Q
2
Q
3
470
Ω
�
+12 V
0.1 µF
(1 M
Ω
12 pF
TEST INPUT)
p-p
TYPICAL LINEARITY = ± 3% AT V = 1 V
TYPICAL SNR = 50dB
TYPICAL R = 375
Ω
TYPICAL V dc = 3.8 V
TYPICAL I = 9 mA
IN
T
O
F
12
3
Q , Q , Q : 2N3904
V
O