SPECIFICATION
90W Single Output LED Driver
NPF-90D series
File Name:NPF-90D-SPEC 2018-01-15
SPECIFICATION
MODEL
CONSTANT CURRENT REGION
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE RANGE
Note.2
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
47 ~ 63Hz
<0.25mA / 277VAC
95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
Compliance to EAC TP TC 020@ load 60%≧EN55015, EN61000-3-2 Class C ( ) ; EN61000-3-3;
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity Line-Line 2KV) EAC TP TC 020;
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
916.7K hrs min. Telcordia SR-332 (Bellcore) ; 231.2K hrs min. MIL-HDBK-217F (25 )℃
1. All parameters NOT specially mentioned are measured at 230VAC input, rated and 25 of ambient temperature.current ℃
2. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
4. The standby power consumption is specified for 230VAC.
5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. The model certified for CCC(GB19510.14, GB19510.1, GB17743 and GB17625.1) is an optional model . Please contact MEAN WELL for details.
7. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃
or less.
8. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude℃℃
higher than 2000m(6500ft).
Shut down o/p voltage, re-power on to recover
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
EMC IMMUNITY
EMC EMISSION
COLD START 60A(twidth=550 s measured at 50% Ipeak) at 230VAC; Per NEMA 410
μ
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
17.5 ~ 21V15 ~ 17V
23 ~ 27V
28 ~ 34V
34 ~ 40V
41 ~ 46V 54 ~ 60V
46 ~ 54V 59 ~ 66V
NPF-90D-15
NPF-90D-12
NPF-90D-20
NPF-90D-24
NPF-90D-30
NPF-90D-36
NPF-90D-42
NPF-90D-48
NPF-90D-54
TOTAL HARMONIC DISTORTION
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER
3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
CURRENT TOLERANCE
±5.0%
CURRENT RIPPLE
5.0% max. @rated current
SET UP TIME
Note.3
500ms/115VAC, 230VAC
90 ~ 305VAC 127 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section)
PF 0.98/115VAC, PF 0.96/230VAC, PF 0.94/277VAC@full load≧≧≧
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 20%(@load 60%/115VC, 230VAC; @load 75%/277VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
<0.5W
STANDBY POWER CONSUMPTION
WORKING TEMP.
Tcase=-40 ~ +85 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)℃
MAX. CASE TEMP.
Tcase=+85℃
6A7.5A 4.5A 3.75A
2.5A
1.88A 1.67A
2.15A
3A
90W90W 90W 90W 90W
90W
90.24W 90.18W
90.3W
9 ~ 15V7.2 ~ 12V 12 ~ 20V 14.4 ~ 24V 18 ~ 30V
21.6 ~ 36V
28.8 ~ 48V 32.4 ~ 54V
25.2 ~ 42V
88% 89% 90% 90% 89% 90% 90% 90% 90%
0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC
171*63*37.5mm (L*W*H)
0.77Kg; 18pcs/14.9Kg/0.82CUFT
UL8750, CSA C22.2 No. 250.13-12, ENEC EN61347-1, EN61347-2-13, EN62384 independent,EAC TP TC 004,
IP67 approved ;Design refer to EN60335-1