15. Damp heat
Specified Value ALL OF BR-SERIES
Inductance change : Within ±10%
No significant abnormality in appearance.
Test Methods and
Remarks
The given sample is soldered to the board and then it is kept at the following conditions.
Temperature 60±2℃
Humidity 90~95%RH
Time 1000 hours.
Recovery : At least 2hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
16. Loading under damp heat
Specified Value ALL OF BR-SERIES
Inductance change : Within ±10%
No significant abnormality in appearance.
Test Methods and
Remarks
The given sample is soldered to the board and then it is kept at the following conditions.
Temperature 60±2℃
Humidity 90~95%RH
Applied current Rated current
Time 1000hours.
Recovery : At least 2hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
17. Low temperature life test
Specified Value ALL OF BR-SERIES
Inductance change : Within ±10%
No significant abnormality in appearance.
Test Methods and
Remarks
The given sample is soldered to the board and then it is kept at the following conditions.
Temperature -40±2℃
Duration 1000hours
Recovery : At least 2hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
18. High temperature life test
Specified Value ALL OF BR-SERIES
Inductance change : Within ±10%
No significant abnormality in appearance.
Test Methods and
Remarks
The given sample is soldered to the board and then it is kept at the following conditions.
Temperature 85±2℃
Duration 1000hours
Recovery : At least 2hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
19. Standard conditions
Specified Value ALL OF BR-SERIES
Standard test condition :
Unless otherwise specified, temperature is 20±15℃ and 65±20%of relative humidity.
When there is any question concerning measurement result: In order to provide
correlation data, the test shall be condition of 20±2℃ of temperature, 65±5% relative
humidity.
Inductance is in accordance with our measured value.