MAX6633/MAX6634/MAX6635
12-Bit Plus Sign Temperature Sensors with
SMBus/I
2
C-Compatible Serial Interface
4 _______________________________________________________________________________________
Typical Operating Characteristics
(V
CC
= +3.3V, T
A
= +25°C, unless otherwise noted.)
50
40
30
20
0
-55 550
110
165
SHUTDOWN SUPPLY CURRENT
vs. TEMPERATURE
MAX6633/4/5 toc01
TEMPERATURE (°C)
SHUTDOWN SUPPLY CURRENT (μA)
10
V
CC
= +5.5V
V
CC
= +3.3V
400
300
200
100
0
-55 550 110 165
AVERAGE SUPPLY CURRENT
vs. TEMPERATURE
MAX6633/4/5 toc02
TEMPERATURE (°C)
AVERAGE SUPPLY CURRENT (μA)
V
CC
= +5.5V
V
CC
= +3.3V
5
-1
10 10k 10M
TEMPERATURE ERROR
vs. SUPPLY NOISE FREQUENCY
0
MAX6633/4/5 toc03
SUPPLY NOISE FREQUENCY (Hz)
TEMPERATURE ERROR (°C)
3
2
1
4
V
IN
= SQUARE WAVE APPLIED TO
V
CC
WITH NO BYPASS
CAPACITOR
V
IN
= 200mVp-p
V
IN
= 200mVp-p
0
30
20
10
40
50
60
70
80
90
100
0 5 10 15 20
RESPONSE TO THERMAL SHOCK
MAX6633/4/5 toc04
TIME (s)
TEMPERATURE (°C)
V
CC
= +5.5V
DEVICE IMMERSED IN +85°C
FLUORINERT BATH
3
2
0
-2
-3
-40 400 80 120 160
TEMPERATURE ERROR
vs. TEMPERATURE
MAX6633/4/5 toc05
TEMPERATURE (°C)
TEMPERATURE ERROR (°C)
V
CC
= +3.3V
V
CC
= +5.5V
Detailed Description
The MAX6633/MAX6634/MAX6635 continuously con-
vert their die temperatures into digital values using their
integrated ADCs. The resulting data is readable at any
time through the SMBus/I
2
C-compatible serial interface.
The device functions as a slave on the SMBus inter-
face, supporting Write Byte, Write Word, Read Byte,
and Read Word commands. Separate addresses can
be configured using the individual address pins.
Figures 5, 6, and 7 show the functional diagrams of the
MAX6633/MAX6634/MAX6635, respectively.
SMBus/I
2
C-Compatible Operation
The MAX6633/MAX6634/MAX6635 are readable and
programmable through their SMBus/I
2
C-compatible
serial interface. Figures 1, 2, and 3 show the timing
details of the clock (SCL) and data (SDA) signals. The
devices function as slaves on the SMBus and support
Write Byte, Write Word, Read Byte, and Read Word
commands. Figure 8 is the MAX6633/MAX6634/
MAX6635 programmer’s model.
Addressing
Separate addresses can be configured using the indi-
vidual address pins. The address of each device is
selected by connecting the address (A_) pins to one of
two potentials: GND or V
CC
. The MAX6635 makes two
address pins available (A0, A1), allowing up to four
devices to be connected to a single bus line. The
MAX6634 makes three address pins available (A0, A1,
A2), allowing up to eight devices to be connected to a
single bus line. The MAX6633 makes four address pins
available (A0, A1, A2, A3), allowing as many as 16
devices to be connected to a single bus line. Table 1
shows the full SMBus/I
2
C address for each device type.
Control Registers (MAX6633)
Three registers control the operation of the MAX6633
(Figure 5 and Tables 2 through 6). The Pointer register
is the first addressed and determines which of the other
two registers is acted upon. The other two are the
Temperature and Configuration registers. The tempera-
ture value is stored as 12 bits plus a sign bit, read only,
and contains the latest temperature data. The true reg-
ister length is 16 bits, with the lower 3 unused in this
part. The digital temperature data contained in the tem-
perature register is in °C, using a two’s-complement
format with 1LSB corresponding to 0.0625°C.
The Configuration register is 8 bits, read/write, and
contains the SMBus timeout disable bit, fault queue
enable bit, and the shutdown bit.
Control Registers (MAX6634)
Six registers control the operation of the MAX6634
(Figure 6 and Tables 2 through 7). The pointer register
is the first addressed and determines which of the other
five registers is acted upon. The other five are the
Temperature, Configuration, High-Temperature
(T
HIGH
), Low-Temperature (T
LOW
), and Hysteresis
(T
HYST
) registers. The temperature value is stored as
12 bits plus a sign bit, read only, and contains the lat-
est temperature data. The true register length is 16 bits,
with the lowest 2 used as status bits, and the third bit
(D2) is unused. The digital temperature data contained
in the temperature register is in °C, using a two’s-com-
plement format with 1LSB corresponding to 0.0625°C.
MAX6633/MAX6634/MAX6635
12-Bit Plus Sign Temperature Sensors with
SMBus/I
2
C-Compatible Serial Interface
_______________________________________________________________________________________ 5
Pin Description
PIN
MAX6633 MAX6634 MAX6635
NAME FUNCTION
1 1 1 SDA Serial Data Input/Output. Open drain.
2 2 2 SCL Serial Clock Input
3 A3 Address Pin
4 4 4 GND Ground
5 5 A2 Address Pin
6 6 6 A1 Address Pin
7 7 7 A0 Address Pin
888 V
CC
Supply Voltage Input. +3.0V to +5.5V. Bypass V
CC
to GND
with a 0.1µF capacitor.
—3 5 ALERT ALERT Output. Open drain.
—— 3 OVERT OVERT Output. Open drain.
MAX6633/MAX6634/MAX6635
12-Bit Plus Sign Temperature Sensors with
SMBus/I
2
C-Compatible Serial Interface
6 _______________________________________________________________________________________
Write Byte Format
S ADDRESS WR
ACK COMMAND ACK DATA ACK P
7 bits 8 bits 8 bits
Slave Address:
equivalent
to chip-select line of a 3-
wire interface
Command Byte: selects
register you are writing to
Data Byte: data goes into the register set by the
command byte
Write Word Format
S ADDRESS WR
ACK COMMAND ACK DATA ACK DATA ACK P
7 bits 8 bits
8 bits
(MSB)
8 bits
(LSB)
Slave Address:
equivalent to chip-select
line of a
3-wire interface
Command Byte:
selects register you
are writing to
Data Bytes: data goes into the
register set by the command
byte
Read Byte Format
S ADDRESS WR
ACK COMMAND ACK S ADDRESS RD ACK DATA /// P
7 bits 8 bits 7 bits 8 bits
Slave Address: equivalent
to chip-select line
Command Byte:
selects register you
are reading from
Slave Address: repeated due to
change in data-flow direction
Data Byte: reads from the
register set by the command
byte
Read Word Format
S ADDRESS WR
ACK COMMAND ACK S ADDRESS RD ACK DATA ACK DATA /// P
7 bits 8 bits 7 bits 8 bits
(MSB)
8 bits
(LSB)
Slave Address:
equivalent to chip-
select line
Command Byte:
selects register you
are reading from
Slave Address: repeated
due to change in data-flow
direction
Data Bytes: reads from the
register set by the command
byte
S = Start condition Shaded = Slave transmission
P = Stop condition /// = Not acknowledged
Figure 1. SMBus Protocols
Figure 2. SMBus Write Timing Diagram
SMBCLK
AB CD
E
FG H
I
J
K
SMBDATA
t
SU:STA
t
HD:STA
t
LOW
t
HIGH
t
SU:DAT
t
HD:DAT
t
SU:STO
t
BUF
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
L
M
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
I = SLAVE PULLS SMBDATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO MASTER
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION, DATA EXECUTED BY SLAVE
M = NEW START CONDITION