VS-VSUD405CW60

VS-VSUD405CW60
www.vishay.com
Vishay Semiconductors
Revision: 03-Nov-16
1
Document Number: 94687
For technical questions within your region: DiodesAmericas@vishay.com
, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
FRED Pt
®
Ultrafast Soft Recovery Diode, 400 A
FEATURES
Ultrafast recovery
UL approved file E222165
Designed for industrial level
Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
BENEFITS
Reduced RFI and EMI
Higher frequency operation
Reduced snubbing
Reduced parts count
DESCRIPTION
FRED Pt
®
diodes are optimized to reduce losses and
EMI/RFI in high frequency power conditioning systems. The
softness of the recovery eliminates the need for a snubber in
most applications. These devices are ideally suited for HF
welding, power converters and other applications where
switching losses are significant portion of the total losses.
PRODUCT SUMMARY
I
F(AV)
400 A
V
R
600 V
Q
rr
(typical) 5000 nC
t
rr
124 ns
Type Modules - Diode, FRED Pt
®
Base common
cathode
Terminal
anode 1
Terminal
anode 2
TO-244
ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL TEST CONDITIONS MAX. UNITS
Cathode to anode voltage V
R
600 V
Continuous forward current per diode I
F(DC)
T
C
= 25 °C 480
A
T
C
= 85 °C 338
T
C
= 132 °C 200
Single pulse forward current per diode I
FSM
T
C
= 25 °C 2880
Maximum power dissipation per diode P
D
T
C
= 25 °C 789
W
T
C
= 124 °C 270
Operating junction and storage
temperatures
T
J
, T
Stg
-40 to +175 °C
ELECTRICAL SPECIFICATIONS PER DIODE (T
J
= 25 °C unless otherwise specified)
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Breakdown voltage V
BR
I
R
= 100 μA 600 - -
V
Forward voltage V
FM
I
F
= 200 A - 1.13 1.36
I
F
= 400 A - 1.27 1.72
I
F
= 200 A, T
J
= 175 °C - 0.92 -
I
F
= 400 A, T
J
= 175 °C - 1.07 -
Reverse leakage current I
RM
T
J
= 175 °C, V
R
= V
R
rated - 0.6 3.0 mA
Series inductance L
S
From top of terminal hole to mounting plane - 5 - nH
VS-VSUD405CW60
www.vishay.com
Vishay Semiconductors
Revision: 03-Nov-16
2
Document Number: 94687
For technical questions within your region: DiodesAmericas@vishay.com
, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Fig. 1 - Typical Forward Voltage Drop Characteristics
(Per Leg)
Fig. 2 - Typical Reverse Current vs. Reverse Voltage
(Per Leg)
DYNAMIC RECOVERY CHARACTERISTICS PER DIODE (T
J
= 25 °C unless otherwise specified)
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Reverse recovery time t
rr
T
J
= 25 °C
I
F
= 50 A,
dI
F
/dt = 500 A/μs,
V
R
= 200 V
- 124 -
ns
T
J
= 125 °C - 222 -
Peak recovery current I
RRM
T
J
= 25 °C - 24 -
A
T
J
= 125 °C - 45 -
Reverse recovery charge Q
rr
T
J
= 25 °C - 1466 -
nC
T
J
= 125 °C - 5000 -
THERMAL - MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL MIN. TYP. MAX. UNITS
Thermal resistance, junction to case
per diode
R
thJC
- - 0.19
°C/Wper module - - 0.095
Thermal resistance, case to heatsink per module R
thCS
-0.10-
Weight
-68- g
-2.4-oz.
Mounting torque 30 (3.4) - 40 (4.6)
lbf · in
(N · m)
Mounting torque center hole 12 (1.4) - 18 (2.1)
Terminal torque 30 (3.4) - 40 (4.6)
Vertical pull - - 80
lbf · in
2" lever pull - - 35
Case style TO-244 (TO-244AB)
1
10
100
1000
0 0.5 1.0 1.5 2.0 2.5
I
F
- Instantaneous Forward Current (A)
V
F
-Forward Voltage Drop (V)
T
J
= 125 °C
T
J
= 25 °C
T
J
= 175 °C
0.001
0.01
0.1
1
10
100
1000
0 100 200 300 400 500 600
I
R
- Reverse Current (μA)
V
R
- Reverse Voltage (V)
T
J
= 175 °C
T
J
= 125 °C
T
J
= 25 °C
VS-VSUD405CW60
www.vishay.com
Vishay Semiconductors
Revision: 03-Nov-16
3
Document Number: 94687
For technical questions within your region: DiodesAmericas@vishay.com
, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Fig. 3 - Maximum Current Rating Capability
(Per Leg)
Fig. 4 - Forward Power Loss Characteristics
Fig. 5 - Typical Reverse Recovery Time vs. dI
F
/dt
Fig. 6 - Typical Reverse Recovery Charge vs. dI
F
/dt
Fig. 7 - Typical Reverse Recovery Current vs. dI
F
/dt)
0
20
40
60
80
100
120
140
160
180
0 50 100 150 200 250 300 350 400 450 500
Allowable Case Temperature (°C)
IF
(AV)
- Average Forward Current (A)
DC
Square wave (D = 0.50)
rated VR applied
0
40
80
120
160
200
240
280
320
360
400
0 40 80 120160200240280320360
Average Power Loss (W)
I
F(AV)
- Average Forward Current (A)
D = 0.20
D = 0.25
D = 0.33
D = 0.50
D = 0.75
DC
RMS limit
80
100
120
140
160
180
200
220
240
260
280
300
320
340
360
100 1000
t
rr
(ns)
dI
F
/dt (A/μs)
T
J
= 125 °C
T
J
= 25 °C
V
R
= 200 V
I
F
= 50 A
0
1000
2000
3000
4000
5000
6000
7000
8000
100 1000
Q
rr
(nC)
dI
F
/dt (A/μs)
T
J
= 125 °C
T
J
= 25 °C
V
R
= 200 V
I
F
= 50 A
0
10
20
30
40
50
60
100 1000
I
rr
(A)
dI
F
/dt (A/μs)
T
J
= 125 °C
T
J
= 25 °C
V
R
= 200 V
I
F
= 50 A

VS-VSUD405CW60

Mfr. #:
Manufacturer:
Vishay / Siliconix
Description:
Rectifiers Output & SW Modules - TO-244 FRED
Lifecycle: