Mask Register (03h)
This register masks the ALERT, OT, THERM, and
FANFAIL outputs. A 1 prevents the corresponding fail-
ures from being asserted on these outputs. The mask
bits do not affect the status register.
Global Configuration Register (04h)
The global configuration register controls the shutdown
mode, power-on reset, SMBus timeout, and tempera-
ture channel 2 source select:
D7: Run/Standby. Normal operation is run (0).
Setting this bit to 1 suspends conversions and puts
the MAX6639 into low-power sleep mode.
D6: Software POR. Writing a 1 resets all registers to
their default values.
D5: SMBus Timeout Disable. Writing a zero enables
SMBus timeout for prevention of bus lockup. When
the timeout function is enabled, the SMBus interface
is reset if SDA or SCL remains low for more than
74ms (typ).
D4: Temperature Channel 2 Source. Selects either
local or remote 2 as the source for temperature chan-
nel 2 register data. Writing a zero to this bit selects
remote 2 for temperature channel 2.
D3: PWM Output Frequency Range. Selects either
the 20Hz to 100Hz range or the 5kHz to 25kHz range
for the PWM outputs (see Table 9).
Extended Temperature Registers (05h and 06h)
These registers contain the extended temperature data
from channels 1 and 2. Bits D[7:5] contain the 3 LSBs
of the temperature data. The bit values are 0.5°C,
0.25°C, and 0.125°C. When bit 0 is set to 1, a diode
fault has been detected.
Channel 1 and Channel 2 ALERT, OT, and THERM
Limits (08h Through 0Dh)
These registers contain the temperatures above which
the ALERT, THERM, and OT status bits set and outputs
assert (for the temperature channels that are not
masked). The data format is the same as that of the
channel 1 and channel 2 temperature registers: the
LSB weight is +1°C and the MSB is +128°C.
2-Channel Temperature Monitor with Dual,
Automatic, PWM Fan-Speed Controller
Maxim Integrated 13
MAX6639/MAX6639F
READ/
WRITE
REGISTER
NO.
ADDRESS
POR
STATE
FUNCTION D7 D6 D5 D4 D3 D2 D1 D 0
W 26h
0011
1100
Fan 1 target
duty cycle
MSB——————LS B
R 27h
0000
0000
Fan 2 current
duty cycle
MSB——————LS B
W 27h
0011
1100
Fan 2 target
duty cycle
MSB——————LS B
R/W 28h
0100
000
Channel 1
minimum
fan-start
temperature
MSB——————LS B
R/W 29h
0100
0000
Channel 2
minimum
fan-start
temperature
MSB——————LS B
R 3Dh
0101
1000
Read device
ID
01011000
R 3Eh
0100
1101
Read
manufacturer
ID
01001101
R 3Fh
0000
0000
Read device
revision
00000000
Table 4. Register Map (continued)
Fan 1 and 2 Configuration 1 (10h and 14h)
The following registers control the modes of operation
of the MAX6639:
D7: PWM Mode. D7 = 1 sets the fan into manual
PWM duty-cycle control mode. Write the target duty
cycle in the fan duty-cycle register. D7 = 0 puts the
fan into RPM control mode. To set RPM manually, set
both fan-control temperature channels (bits D2 and
D3) to zero and write the desired tachometer count
into the TACH count register.
D[6:4]: Fan Duty-Cycle Rate-of-Change. D[6:4]
sets the time between increments of the duty cycle.
Each increment is 1/120 of the duty cycle. By adjust-
ing the rate-of-change, audibility of fan-speed
changes can be traded for response time. Table 5
shows the effect of D[6:4] and, for reference, the time
required for the fan speed to change from 33% to
100% duty cycle as a function of the rate-of-change
bits.
D[3:2]: Temperature Channel(s) for Fan Control.
Selects the temperature channel(s) that control the
PWM output when the MAX6639 is in automatic RPM
control mode (PWM mode bit is zero). If two chan-
nels are selected, the fan goes to the higher of the
two possible speeds. If neither channel is selected,
then the fan is in manual RPM mode and the speed
is forced to the value written to the target tach count
register 22h or 23h.
D[1:0]: RPM Range. Scales the tachometer counter
by setting the maximum (full-scale) value of the RPM
range to 2000, 4000, 8000, or 16,000. (Table 3
shows the internal clock frequency as a function of
the range.)
2-Channel Temperature Monitor with Dual,
Automatic, PWM Fan-Speed Controller
14 Maxim Integrated
MAX6639/MAX6639F
A C T U A L R A T E O F CH A N G E AT SPEC IF I C PW M FREQUENCIES
REGISTER 10h
OR 14h D[6:4]
NOMINAL RATE
OF CHANGE (s)
100Hz (s) 50Hz (s) 33.3Hz (s) 20Hz (s)
NOMINAL TIME FROM
33% TO 100% (s)
000 0 0000 0
001 0.0625 0.06 0.06 0.06 0.05 5
010 0.125 0.13 0.12 0.12 0.15 10
011 0.25 0.25 0.26 0.24 0.25 20
100 0.5 0.5 0.5 0.51 0.5 40
101 1 1 1 0.99 1 80
110 2 2 2 1.98 2 160
111 4 4 4 3.96 4 320
Table 5. Fan Duty-Cycle Rate-of-Change
REGISTER 10h OR 14h FAN MAXIMUM RPM VALUE
00 2000
01 4000
10 8000
11 16,000
Table 6. Fan RPM Speed
MAXIMUM RPM VALUE ACTUAL RPM
SELECTED NUMBER
OF PULSES PER
REVOLUTION
ACTUAL FAN PULSES
PER REVOLUTION
TACHOMETER COUNT
VALUE*
2000 1000 2 2 3Ch
4000 1000 2 2 78h
4000 3000 2 2 28h
4000 3000 2 4 14h
16,000 8000 4 4 3Ch
16,000 8000 4 2 78h
Table 7. RPM-to-Tachometer Count Relationship Examples
*
Tachometer count value = ((internal clock frequency) x 60) / actual RPM) (selected number of pulses per revolution / actual fan pulses)
Fan 1 and 2 Configuration 2a (11h and 15h)
The following registers apply to the automatic RPM con-
trol mode:
D[7:4]: Fan RPM (Tachometer) Step-Size A.
Selects the number of tachometer counts the target
value decreases for each temperature step increase
above the fan-start temperature. Value = n + 1 (1
through 16) where n is the value of D[7:4].
D[3:2]: Temperature Step Size. Selects the temper-
ature increment for fan control. For each temperature
step increase, the target tachometer count decreas-
es by the value selected by D[7:4] (Table 8).
D1: PWM Output Polarity. PWM output is low at
100% duty cycle when this bit is set to zero. PWM
output is high at 100% duty cycle when this bit is set
to 1.
D0: Minimum Speed. Selects the value of the mini-
mum fan speed (when temperature is below the fan-
start temperature in the automatic RPM control
mode). Set to zero for 0% fan drive. Set to 1 to deter-
mine the minimum fan speed by the tachometer
count value in registers 22h and 23h (fan maximum
TACH).
Fan 1 and 2 Configuration 2b (12h and 16h)
The following registers select the tachometer step sizes
and number of steps for step-size A to step-size B
slope changes (see Figure 1):
D[7:4]: RPM (Tachometer) Step Size B. Selects
number of tachometer counts the target value
decreases for each temperature step increase after
the number of steps selected by D[3:0]. Value = n +
1 (1 through 16) where n is the value of D[7:4].
D[3:0]: Selects the number of temperature/tachome-
ter steps above the fan-start temperature at which
step-size B begins.
Fan 1 and Fan 2 Configuration 3 (13h and 17h)
The following registers control fan spin-up, PWM output
frequency, pulse stretching, and THERM to fan full-
speed enable:
D7: Fan Spin-Up Disable. Set to zero to enable fan
spin-up. Whenever the fan starts up from zero drive,
it is driven with 100% duty cycle for 2s to ensure that
it starts. Set to 1 to disable the spin-up function.
D6: THERM to Full-Speed Enable. When this bit is
1, THERM going low (either by being pulled low
externally or by the measured temperature exceed-
ing the THERM limit) forces the fan to full speed. In
all modes, this happens at the rate determined by
the rate-of-change selection. When THERM is
deasserted (even if the fan has not reached full
speed), the speed falls at the selected rate-of-
change to the target speed.
D5: Disable Pulse Stretching. Pulse stretching is
enabled when this bit is set to zero. When modulat-
ing the fan’s power supply with the PWM signal, the
PWM pulses are periodically stretched to keep the
tachometer signal available for one full revolution.
Setting this bit to 1 disables pulse stretching. The
MAX6639 still measures the fan speed but does not
stretch the pulses for measurements, so the fan’s
power supply must not be pulse modulated.
D[1:0]: PWM Output Frequency. These bits control
the PWM output frequency as shown in Table 9.
Fan Tach Count 1 and 2 (20h and 21h)
These registers have the latest tachometer measure-
ment of the corresponding channel. This is inversely
proportional to the fan’s speed. The fan RPM range
should be set so this count falls in the 30 to 160 range
for normal fan operation.
Fan Start Tach Count/Target Tach Count
(22h and 23h)
D[7:0]: This sets the starting tachometer count for the
fan in automatic RPM mode. Depending on the setting
of the minimum duty-cycle bit, the tachometer count
has this value either at all temperatures below the fan-
start temperature or the count is zero below the fan-
start temperature and has this value when the fan-start
temperature is reached. These registers are the target
tach count when in manual RPM mode.
2-Channel Temperature Monitor with Dual,
Automatic, PWM Fan-Speed Controller
Maxim Integrated 15
MAX6639/MAX6639F
REGISTER 11h
OR 15h
FAN CONTROL TEMPERATURE
STEP SIZE (°C)
00 1
01 2
10 4
11 8
Table 8. Temperature Step Size
REGISTERS
13h AND 16h
LOW-FREQUENCY
(Hz) REGISTER
04h D3 = 0
HIGH-FREQUENCY
(kHz) REGISTER
04h D3 = 1
00
20 5
01
33.33 8.33
10
50 12.5
11
100 25
Table 9. Fan PWM Frequency