BP5512A

1/1
5V/200mA Output
Isolated DC/DC converter
BP5512A
Data Sheet
2012.06 -
Rev. A
www.rohm.com
© 2012 ROHM Co., Ltd. All rights reserved.
Unit Conditions
(Ta=25°C
)
V
V
mA
V
V
mVp-p
%
Io=50 to 200mA
DC
Parameter Symbol Typ. Max.Min.
Vi
Vo
Io
Vr
Vl
Vp
η
5.0
5.0
0.05
0.05
50
62
6.5
5.5
200
0.1
0.2
200
4.5
4.5
0
57
External Components Settings
Use a fuse for safety.
220μF / 25V Low impedance type for power supply
F1: Fuse
C2: Output capacitor
220μF / 25V Low impedance type for power supply
C2: Output capacitor
Pin No.
1
2
3
4
5
6
7
Function
Input terminal
GND terminal
Non pin
Non pin
Output common terminal
Non pin
Output terminal
Pin Name
Vi
GND
Non pin
Non pin
COM
Non pin
Vo
Input voltage
Operating temperature range
Storage temperature range
Allowable maximum
surface temperature
Maximum output current
Withstand voltage
Parameter
Conditions
Symbol
Vi
Topr
Tstg
Tcmax
Iomax
VI
Limits
8
20 to +85
40 to +85
105
200
AC2300
Unit
V
°C
°C
°C
mA
V
Ambient temperature +
the module self-heatingTcmax
Between input and output, 1 minute
DC
Vi=4.5 to 6.5V
(Unless otherwise noted, Vi=5.0V, Io=200mA, Ta=25°C)
C1
BP5512
Vo
(5V/200mA)
+
Vi
C2
GND
+
COM
1
2 5 7
BP5512A
1
2 5 7
0.75±0.1
1.3±0.2
P=2.54±0.2
2.54X6=15.24TYP.
1 2 5 7
9.13MAX.
21.4MAX
3.5
+0.5
1.0
0.5±0.05
11.05MAX.
6.15MAX.
MARKING SIDE
28.2MAX 17.2MAX
0
50
100
150
200
250
300
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100
Ambient temperature Ta
(°C)
(Vi=5V)
Output current Io
(mA)
OPERATION RANGE
0
10
20
30
40
50
60
70
80
0 50 100 150 200
Conversion Efficiency η(%)
Output Current Io(mA)
(Vi=5.0V, Ta=25°C)
Refer to derating curve
1
1 The load should be reduced according to the surrounding temperature, input voltage.
Absolute Maximum Ratings
Electrical Characteristics
Input voltage
Output voltage
Output current
Line regulation
Load regulation
Output ripple voltage
Power conversion efficiency
Test Circuit
Use a fuse for safety.
Dimensions (Unit : mm)
Derating Curve
Conversion Efficiency
R1120A
www.rohm.com
© 2012 ROHM Co., Ltd. All rights reserved.
Notice
ROHM Customer Support System
http://www.rohm.com/contact/
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specied herein is subject to change for improvement without notice.
The content specied herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specied in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specied herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specied in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, ofce-automation equipment, commu-
nication devices, electronic appliances and amusement devices).
The Products specied in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, re or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, re control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuel-
controller or other safety device). ROHM shall bear no responsibility in any way for use of any
of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specied herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.

BP5512A

Mfr. #:
Manufacturer:
ROHM Semiconductor
Description:
Switching Voltage Regulators Isolated DC/DC Converter
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet