HE-S (AHES3, 4)
–6–
ASCTB360E 201604-T
NOTES
1. For cautions for use, please refer to our web site.
(https://www3.panasonic.biz/ac/e/control/relay/cautions_use/index.jsp)
2. When coil holding voltage controlled by PWM, check coil holding voltage and operation of relay under the actual
condition.
3. Usage, transport and storage conditions
1) Temperature:
–40 to +55°C –40 to +131°F (When applied coil holding voltage is 30% to 110%V of nominal coil voltage)
–40 to +85°C –40 to +185°F (When applied coil holding voltage is 30% to 60%V of nominal coil voltage or storage)
2) Humidity: 5 to 85% RH (Not freezing and condensing at low temperature)
In addition the humidity range depends on temperature. The allowable ranges are as follows;
3) Air pressure: 86 to 106 kPa
Allowable range of temperature and humidity for operation, transport and storage.
4. Solder and cleaning conditions
1) Please obey the following conditions when soldering automatically.
(1) Pre-heating: within 120°C 248°F (solder surface terminal portion) and within 120 seconds
(2) Soldering iron: 260°C±5°C 500°F±41°F (solder temperature) and within 10 seconds (soldering time)
2) In case of manual soldering, following conditions should be observed.
• Max. 270°C 518°F (solder temperature) within 10 seconds (soldering time)
• Max. 350°C 662°F (solder temperature) within 5 seconds (soldering time)
* Effects of soldering heat on the relays vary depending on the PC board. So please confirm actual soldering condition with the PC
board used for assembling.
3) Do not clean this relay by immersion, since the relay is not sealed.
Also, be careful not to allow flux to overflow above the PC board or enter the inside of the relay.
[Coil holding voltage: 30% to 110%V] [Coil holding voltage: 30% to 60%V]
–40 0 55
–40 +32 +131
5
85
Humidity, %RH
Temperature, °C °F
Tolerance range
(Avoid
condensation
when used at
temperatures
higher than
0°C
(Avoid freezing
when used at
temperatures
lower than
0°C
32°F)
32°F)
–40 0 85
–40 +32 +185
5
85
Humidity, %RH
Temperature, °C °F
Tolerance range
(Avoid freezing
when used at
temperatures
lower than
0°C
(Avoid
condensation
when used at
temperatures
higher than
0°C
32°F)