ACPL-M483/P483/W483
Inverted Logic High CMR Intelligent Power Module
and Gate Drive Interface Optocoupler
Data Sheet
CAUTION: It is advised that normal static precautions be taken in handling and assembly
of this component to prevent damage and/or degradation which may be induced by ESD.
Description
The ACPL-M483/P483/W483 fast speed optocoupler
contains a AlGaAs LED and photo detector with built-in
Schmitt trigger to provide logic-compatible waveforms,
eliminating the need for additional wave shaping. The
totem pole output eliminates the need for a pull up
resistor and allows for direct drive of Intelligent Power
Module or as a gate driver. Minimized propagation delay
di erence between devices makes these optocouplers
excellent solutions for improving inverter e ciency
through reduced switching dead time.
Applications
IPM Interface Isolation
Isolated IGBT/MOSFET Gate Drive
AC and Brushless DC Motor Drives
Industrial Inverters
General Digital Isolation
Functional Diagram
Note: A 0.1 F bypass
capacitor must be con-
nected between pins Vcc
and Ground.
Truth Table
(Negative Logic)
LED V
O
ON LOW
OFF HIGH
Truth Table Guaranteed:
Vcc from 4.5 V to 30 V
Features
Inverted output type (totem pole output)
Truth Table Guaranteed: Vcc from 4.5 V to 30 V
Performance Speci ed for Common IPM Applications
Over Industrial Temperature Range.
Short Maximum Propagation Delays
Minimized Pulse Width Distortion (PWD)
Very High Common Mode Rejection (CMR)
Hysteresis
Available in SO-5 (ACPL-M483) and Stretched SO-6
package (ACPCL-P483/W483).
Package Clearance/Creepage at 8 mm (ACPL-W483)
Safety Approval:
– UL Recognized with 5000 V
rms
(ACPL-W483) for 1
minute per UL1577.
– CSA Approved.
– IEC/EN/DIN EN 60747-5-5 Approved with V
IORM
=
567 V
peak
for ACPL-M483 and V
IORM
= 891 V
peak
for
ACPL-P483 and V
IORM
= 1140 V
peak
for ACPL-W483,
under option 060.
Speci cations
Wide operating temperature range: -40°C to 105°C.
Maximum propagation delay t
PHL
/t
PLH
= 120/120 ns
Maximum Pulse Width Distortion (PWD) = 50 ns.
Propagation Delay Di erence Min/Max = –100/100 ns
Wide Operating V
CC
Range: 4.5 to 30 Volts
30 kV/s minimum common mode rejection (CMR) at
V
CM
= 1000 V.
Ground
V
CC
Anode
Cathode
V
O
61
5
43
SHIELD
Ground
V
CC
Anode
N.C.
Cathode
V
O
61
52
43
SHIELD
ACPL-M483