PPT2-0001GRR5VE

PPT2 Next Generation
Precision Pressure Transducer
Highly Accurate Over a Wide Temperature Range
Honeywell’s Next Generation Precision Pressure Transducer (PPT2)
combines proven silicon sensor technology with microprocessor-based
signal conditioning to provide an extremely smart pressure transducer.
Available in a compact, rugged design, the PPT2 has many software
features that support a wide range of digital and analog applications.
PERFORMANCE
Total Error Band
(1) (2)
Digital: ±0.075% FS Max.
Analog: ±0.09% FS Max.
Temperature Range Operating: 40 to 85ºC Standard (S), 55 to 110°C Extended (E)
Storage: 50 to 100°C Standard (S), 60 to 125°C Extended (E)
Reading Rate
(4)
1000 readings/sec to 42.67min/reading
Resolution Digital: Up to 0.001% FS, Analog: 0.1mV typical (15+ bits)
Minimum Response
Delay
2 ms
Long Term Stability 0.025%FS max per year typical
MECHANICAL
Pressure Units
(4)
atm, bar, cmwc, ftwc, hPa, inHg, inwc, kg/cm2, Kpa, mBar,
mmHg, Mpa, mwc, psi, user, pfs
Media Compatibility Suitable for non-condensing, non-corrosive, and non-combustible gases
Weight 4.4 oz. (125 gm) without fi ttings
ELECTRICAL
Output
(4) (5)
RS232 Digital with 05V Analog, RS485 Digital with 05V Analog
Power Requirements Supply Voltage: 6.0 to 34 VDC, Operating Current: 50 mA maximum
Baud Rate
(4)
1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600,
115200
Bus Addressing
(4)
Address up to 89 units
Connector MILC26482, Shell Size #10, 6-pin, #20 size
ENVIRONMENTAL
Overpressure
(3)
3X FS, maximum 600psi
Burst Pressure
(3)
3X FS, maximum 700psi
EMC Directive Compliant
RoHS Compliant
Specifications
(1) Accuracy is the sum of worst case linearity, repeatability, hysteresis, thermal effects and
calibration errors over the operating temperature range. Full scale for differential ranges is the sum
of + and – ranges. Pressure range 1psi gauge has digital accuracy of ±0.15% FS maximum; analog
accuracy of ±0.18% FS maximum. Calibration is traceable to NIST. (2) Tighter accuracy available on
some models - consult factory. (3) Exposure to overpressure will not permanently affect calibration
or accuracy of unit. Burst pressure is the sum of the measured pressure plus the static pressure and
exceeding it may result in media escape. (4) User confi gurable. (5) Recommended load impedance
of 100 k-ohm or greater.
POTENTIAL APPLICATIONS
Secondary Air Data
• Altimeters
• Engine Testing
• Flight Testing
• Meteorology
Flow and Pressure Calibrators
Instrumentation and Analytical Equipment
• Process Control
Research and Development
FEATURES & BENEFITS
• HIGHLY ACCURATE
±0.075%FS total accuracy over operating
temperature range
Simplifi es System Design
No additional signal compensation needed to
gain the benefi ts of a very accurate sensor
SMART, DIGITAL SENSING AND CONTROL
Effi cient Data Acquisition
Network up to 89 units
Easy Interface
Connects to PC via communication ports
VERSATILE AND CONFIGURABLE
Works with existing and new systems
05V analog and either RS232 or RS485 digital
output
Handles most dry gas media
Optimizes Output
User-confi gurable pressure units, sampling,
update rate
Flags Problems
Internal diagnostics set fl ags, indicates errors
USER SELECTABLE SOFTWARE FEATURES
Baud Rate, Parity Setting, Continuous
Broadcast, ASCII or Binary Output, Sensor
Temperature Output (°C), Deadband, Sensitivity,
Tare Value, Confi gurable Analog Output
CE QUALIFIED. ISO-9001, ISO-14001
F
G
K
R
W
X
OPTION B
OPTION C
Ordering Information
Full Scale Pressure Range Absolute Gauge Differential
0001 N/A 1 PSI
(1)
±1 PSI
0002 N/A 2 PSI ±2 PSI
0005 N/A 5 PSI ±5 PSI
0010 N/A 10 PSI ±10 PSI
0015 15 PSI N/A N/A
0020 20 PSI 20 PSI ±20 PSI
0050 50 PSI 50 PSI ±50 PSI
0100 100 PSI 100 PSI ±100 PSI
0300 300 PSI 300 PSI ±300 PSI
0500 500 PSI 500 PSI ±500 PSI
TYPE P1 PRESSURE P2 PRESSURE
A Absolute 0(vacuum) to FS N/A
G Gauge Reference to FS Reference
D Differential +FS to FS rel. to P2 +FS to FS rel. to P1
P1 PRESSURE CONNECTION (ABSOLUTE, GAUGE, DIFFERENTIAL)
F Filter (blocks debris)
G Stainless SwagelokTM (1/8 inch female)
K Stainless Swagelok-compatible (1/8 inch male)
R Brass barbed, right angle (1/8 inch ID tubing)
W Brass barbed (1/8 inch ID tubing)
X Brass SwagelokTM (1/8 inch female)
P2 PRESSURE CONNECTION (GAUGE, DIFFERENTIAL)
F Filter (blocks debris)
G Stainless SwagelokTM (1/8 inch female)
K Stainless Swagelok-compatible (1/8 inch male)
R Brass barbed, right angle (1/8 inch ID tubing)
W Brass barbed (1/8 inch ID tubing)
X Brass SwagelokTM (1/8 inch female)
N Not Applicable (Absolute)
OUTPUTS
2V RS232 digital, 05V analog
5V RS485 digital, 05V analog
OPERATING TEMPERATURE RANGE
S Standard: 40 to 85°C
E Extended: 55 to 110°C
OPTIONS
B Mating Connector (See Below)
C Power Supply/Data Cable (RS232 only, See Below)
E Certifi cate of Conformance
F Calibration Certifi cate
PPT2
PPT2 Specifi cations
Honeywell Aerospace
1944 East Sky Harbor Circle
Phoenix, AZ 85034
aerospace.honeywell.com
N61-1598-000-000 | 10/16
© 2016 Honeywell International Inc.
Signal Name
A RS-232 (TD) / RS-485 (B)
B RS-232 (RD) / RS-485 (A)
C Case Ground
D Common Ground
E DC Power In
F Analog Output
Dimensions
(2)
Honeywell reserves the right to make changes to improve
reliability, function or design. Honeywell does not assume
any liability arising out of the application or use of any
product or circuit described herein; neither does it convey
any license under its patent rights nor the rights of others.
(1) Pressure range 1psi gauge has digital accuracy of
±0.15% FS maximum; analog accuracy of ±0.18%
FS maximum.
(2) See application note AN106 “Mechanically
Mounting the PPT2 in Legacy PPT Applications”,
at www.pressuresensing.com.
ESD (electrostatic discharge) sensitive device
Damage may occur when subjected to high
energy ESD. Proper ESD precautions should
be taken to avoid performance degradation or
loss of functionality.
EOS (electrical overstress) sensitive device
Damage may occur when subjected to
EOS. Do not exceed specifi ed ratings to
avoid performance degradation or loss of
functionality.
Find out more
For more information on Honeywell’s Precision Pressure
Transducers visit us online at www.pressuresensing.com.
Customer Service Email: quotes@honeywell.com
1.34
(34)
1.43
(36.3)
1.56
(39.5)
2.18
(55.4)
.48
(12.2)
.65
(16.4)
1.48
(37.5)
2.20
(55.9)
2.48
(62.9)
.68
(17.4)
.46
(11.7)
1.08
(27.3)
.54
(13.7)
2.13
(54.1)
.97
(24.5)
PRECISION PRESSURE TRANSDUCER
PPT2 0020 A W N 2V S - A

PPT2-0001GRR5VE

Mfr. #:
Manufacturer:
Description:
PPT2 MV 5V 1FS -55TO110 1PSIG
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union