PPT2 Next Generation
Precision Pressure Transducer
Highly Accurate Over a Wide Temperature Range
Honeywell’s Next Generation Precision Pressure Transducer (PPT2)
combines proven silicon sensor technology with microprocessor-based
signal conditioning to provide an extremely smart pressure transducer.
Available in a compact, rugged design, the PPT2 has many software
features that support a wide range of digital and analog applications.
PERFORMANCE
Total Error Band
(1) (2)
Digital: ±0.075% FS Max.
Analog: ±0.09% FS Max.
Temperature Range Operating: 40 to 85ºC Standard (S), 55 to 110°C Extended (E)
Storage: 50 to 100°C Standard (S), 60 to 125°C Extended (E)
Reading Rate
(4)
1000 readings/sec to 42.67min/reading
Resolution Digital: Up to 0.001% FS, Analog: 0.1mV typical (15+ bits)
Minimum Response
Delay
2 ms
Long Term Stability 0.025%FS max per year typical
MECHANICAL
Pressure Units
(4)
atm, bar, cmwc, ftwc, hPa, inHg, inwc, kg/cm2, Kpa, mBar,
mmHg, Mpa, mwc, psi, user, pfs
Media Compatibility Suitable for non-condensing, non-corrosive, and non-combustible gases
Weight 4.4 oz. (125 gm) without fi ttings
ELECTRICAL
Output
(4) (5)
RS232 Digital with 05V Analog, RS485 Digital with 05V Analog
Power Requirements Supply Voltage: 6.0 to 34 VDC, Operating Current: 50 mA maximum
Baud Rate
(4)
1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600,
115200
Bus Addressing
(4)
Address up to 89 units
Connector MILC26482, Shell Size #10, 6-pin, #20 size
ENVIRONMENTAL
Overpressure
(3)
3X FS, maximum 600psi
Burst Pressure
(3)
3X FS, maximum 700psi
EMC Directive Compliant
RoHS Compliant
Specifications
(1) Accuracy is the sum of worst case linearity, repeatability, hysteresis, thermal effects and
calibration errors over the operating temperature range. Full scale for differential ranges is the sum
of + and – ranges. Pressure range 1psi gauge has digital accuracy of ±0.15% FS maximum; analog
accuracy of ±0.18% FS maximum. Calibration is traceable to NIST. (2) Tighter accuracy available on
some models - consult factory. (3) Exposure to overpressure will not permanently affect calibration
or accuracy of unit. Burst pressure is the sum of the measured pressure plus the static pressure and
exceeding it may result in media escape. (4) User confi gurable. (5) Recommended load impedance
of 100 k-ohm or greater.
POTENTIAL APPLICATIONS
• Secondary Air Data
• Altimeters
• Engine Testing
• Flight Testing
• Meteorology
• Flow and Pressure Calibrators
• Instrumentation and Analytical Equipment
• Process Control
• Research and Development
FEATURES & BENEFITS
• HIGHLY ACCURATE
±0.075%FS total accuracy over operating
temperature range
Simplifi es System Design
No additional signal compensation needed to
gain the benefi ts of a very accurate sensor
• SMART, DIGITAL SENSING AND CONTROL
Effi cient Data Acquisition
Network up to 89 units
Easy Interface
Connects to PC via communication ports
• VERSATILE AND CONFIGURABLE
Works with existing and new systems
05V analog and either RS232 or RS485 digital
output
Handles most dry gas media
Optimizes Output
User-confi gurable pressure units, sampling,
update rate
Flags Problems
Internal diagnostics set fl ags, indicates errors
• USER SELECTABLE SOFTWARE FEATURES
Baud Rate, Parity Setting, Continuous
Broadcast, ASCII or Binary Output, Sensor
Temperature Output (°C), Deadband, Sensitivity,
Tare Value, Confi gurable Analog Output
• CE QUALIFIED. ISO-9001, ISO-14001