Electrical specifications and ordering codes
Type
I
R
mA
I
S
mA
I
Smax
(V = V
max
)
A
I
r
(typ.)
(V = V
max
)
mA
R
R
Ω
R
min
Ω
IECQ
Approvals Ordering code
C830 525 1050 7.0 24 3.7 2.2 X B59830C0160A070
C840 400 800 4.1 18 6 3.6 X B59840C0160A070
C850 250 500 2.2 16 10 6.0 X B59850C0160A070
C860 180 360 1.5 13 15 7.8 X B59860C0160A070
C870 125 250 1.0 11 25 13.1 X B59870C0160A070
C880 70 140 0.4 8 70 36.7 X X B59880C0160A070
C890 35 70 0.2 6 150 78.7 X X B59890C0160A070
Reliability data
Test Standard Test conditions ∆R
25
/R
25
Electrical endurance,
cycling
IEC 60738-1 Room temperature, I
Smax
; V
max
Number of cycles: 100
< 25%
Electrical endurance,
constant
IEC 60738-1 Storage at V
max
and T
op,max
(@ V
max
)
Test duration: 1000 h
< 25%
Damp heat IEC 60738-1 Temperature of air: 40 °C
Relative humidity of air: 93%
Duration: 56 days
Test according to IEC 60068-2-78
< 10%
Rapid change
of temperature
IEC 60738-1 T
1
= T
op,min
(0 V), T
2
= T
op,max
(0 V)
Number of cycles: 5
Test duration: 30 min
Test according to IEC 60068-2-14, test Na
< 10%
Vibration IEC 60738-1 Frequency range: 10 to 55 Hz
Displacement amplitude: 0.75 mm
Test duration: 3 × 2 h
Test according to IEC 60068-2-6, test Fc
< 5%
Shock IEC 60738-1 Acceleration: 400 m/s
2
Pulse duration: 6 ms; 6 × 5000 pulses
< 5%
Climatic sequence IEC 60738-1 Dry heat: T = T
op,max
(0 V)
Test duration: 16 h
Damp heat first cycle
Cold: T = T
op,min
(0 V)
Test duration: 2 h
Damp heat 5 cycles
Tests performed according to
IEC 60068-2-30
< 10%
Overcurrent protection
Leaded disks, coated, 110 V C830 ... C890
Page 3 of 11Please read Cautions and warnings and