CINT1200A2475K01

CINT1200
200W Single Output
Industrial Series
www.slpower.com CINT1200 REV 1.3 12-NOV-12 1
Features
3” x 5” x 1.3” Package
200W with 100LFM Air
180W Convection Cooled
Class B Conducted EMI
Fits 1U Applications
Universal Input 90-264 Vac
Approved to CSA/EN/IEC/UL60950-1, 2
nd
Edition
Efficiency 90% typical
3 Year Warranty
RoHS Compliant
Description
A power-packed, highly efficient AC to DC power supply designed for industrial and ITE applications. These models
provide 180 Watts convection cooled, 200 Watts with moving air. The small heat footprint allows simple thermal design of
systems which use this product. All models are CE marked to low voltage directive and approved to ITE standards of
EN60950-1, 2nd edition.
Model Selection
Model
Output
Current
Minimum
Ripple &
Total
OVP
Number
w/1
00LFM air
Convection
*
Load
Noise**
Regulation
Threshold***
CINT1200A1275K01 12V 16.7A 15.0A 0A 120mV pk-pk
3% 14.0 1.1V
CINT1200A1575K01 15V 13.3A 12.0A 0A 150mV pk-pk
3%
18.5 ± 1.2V
CINT1200A1875K01 18V 11.1A 10.0A 0A 180mV pk-pk
3%
21.5 ± 2.0V
CINT1200A2475K01 24V 8.33A 7.50A 0A 240mV pk-pk
3%
29.0 ± 2.5V
CINT1200A2875K01 28V 7.14A 6.40A 0A 280mV pk-pk
3%
33.5 ± 2.5V
CINT1200A3275K01 32V 6.25A 5.62A 0A 320mV pk-pk
3%
36.0 ± 3.0V
CINT1200A3675K01 36V 5.55A 5.00A 0A 360mV pk-pk
3%
41.0 ± 3.0V
CINT1200A4875K01 48V 4.17A 3.75A 0A 480mV pk-pk
3%
56.0 ± 3.0V
Notes: * Total convection power is 180 Watts.
** Measured with noise probe directly across output terminals, and load terminated with 0.1μF ceramic and 10μF low ESR capacitors.
General Specifications
AC Input
100-240Vac, ±10%, 47-63Hz, 1
120–370Vdc
Turn On Time
Less than 3 sec. @115Vac, Full Load
Input Current
115Vac: 1.8A, 230Vac: 0.9A
Hold-up Time
16mS at 200W, 120Vac/60Hz
CINT1200
200W Single Output
Industrial Series
www.slpower.com CINT1200 REV 1.3 12-NOV-12 2
Specifications (continued)
Inrush Current
264Vac, cold start: will not exceed 55A
Overtemperature
Protection
Sensing transformer temperature, 165°C at
full load, latching type, requires input power
recycling to reset.
Input Fuses
F1, F2: 3.15A, 250Vac fuses provided on all
models
Overload Protection
120 to 150% of rating, Hiccup Mode
Earth Leakage
Current
<500μA@264Vac, 60Hz, NC; <1mA SFC
Short Circuit
Protection
Hiccup Mode, auto recovery.
Efficiency
88% typical
Overvoltage
Protection
OVP latch, see models chart for trip range.
Output Power
200W continuous, with 100 lfm airflow, 180W
convection cooled – See chart for specific
voltage model ratings.
Switching Frequency
PFC: Fixed, 65kHz
Main Converter: Variable 35-200kHz, 65-
70kHz at full load.
Transient
Response
500µS typical, return to 0.5% of nominal, 50%
load step. i/t: <0.2A/μS. Max Voltage
Deviation = 3%
Isolation
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 1500Vac
Ripple and Noise
0.5%rms, 1% pk-pk, see chart.
Operating
Temperature
-10°C to +70°C
Start Up at -40°C, full load
Output Voltage
See chart
Temperature
Derating
Derate output power linearly above 50°C to
50% at 70°C
Voltage
Adjustability
+/-
5% from nominal
Storage Temperature
-40°C to +85°C
Minimum Load
Not required
Altitude
Operating: -500 to 10,000 ft.
Non-operating: -500 to 40,000 ft.
Total Regulation
+/- 3% combined line, load and initial setting.
Relative Humidity
5% to 95%, non-condensing
Vibration
Operating: 0.003g
²
/Hz, 1.5grms overall, 3
axes, 10 min/axis
Non-Operating: 0.026g²/Hz, 5.0grms overall,
3 axes, 1 hr/axis
Shock
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6
shocks total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3
axes, 6 shocks total
Dimensions
W: 3.0” x L: 5.0” x H: 1.3”
Safety Standards
EN/CSA/UL/IEC 60950-1, 2nd Edition
Weight
325g
MTBF
405,000 hours, 25°C, 110Vac
Output vs. Temperature Derating Curve
180W convection cooled and 200W continuous with 100 LFM airflow, derate output power to 50% at 70C.
CINT1200
200W Single Output
Industrial Series
www.slpower.com CINT1200 REV 1.3 12-NOV-12 3
EMI/EMC Compliance
Conducted Emissions
EN55011/22 Class B, FCC Part 15, Subpart B, Class B
Radiated Emissions
EN55011/22 Class A, FCC Part 15, Subpart B, Class A w/6db margin
Static Discharge Immunity
EN61000-4-2, 6kV Contact Discharge, 8kV air discharge
Radiated RF Immunity
EN61000-4-3, 3V/m.
EFT/Burst Immunity
EN61000-4-4, 2kV/5kHz
Line Surge Immunity
EN61000-4-5, 1kV differential, 2kV common-mode
Conducted RF Immunity
EN61000-4-6, 3Vrms
Power Frequency Magnetic Field Immunity
EN61000-4-8, 3A/m
Voltage Dip Immunity
EN61000-4-11, 100%, 10ms; 30%, 275ms; 60%, 100ms; Performance
Criteria A, A, & A at 70% load.
Line Harmonic Emissions
EN61000-3-2, Class A, B, C, & D
Flicker Test
EN61000-3-3, Complies (dmax<6%)
Mechanical Drawing
Notes: 1. All dimensions in inches (mm), tolerance
is +/-0.000”.
2. Mounting holes should be grounded for
EMI purposes.
3. FG is safety ground connection.
4. The power supply requires mounting on
metal standoffs 0.20” (5mm) in height, min.
Connector Information
Input Connector
J100
Ground
(FG)
DC Output Connector
J300
PIN 1) AC LINE
PIN 2) EMPTY
PIN 3) AC NEUTRAL
0.25” FASTON TAB
Term. 1,2,3: RTN
Term. 4,5,6: +Vout
Mating Connector:
AMP Molex 640250-3
Pins: 640252-2
Mating Connector:
Molex 01-90020001
Mating Connector:
AMP 640250-6
Pins: 640252-2
Data Sheet © 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.

CINT1200A2475K01

Mfr. #:
Manufacturer:
Description:
Switching Power Supplies 200W 24 V 7.5 A Out 24V 7.50A/8.33A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union