183
SIDACtor
®
Protection Thyristors
© 2009 Littelfuse, Inc.
Specifications are subject to change without notice.
Please refer to www.littelfuse.com for current information.
High Surge Current Protection
High Surge Current Series
The High Surge Current DO-214 Series are SIDACtor
®
devices designed to protect equipment located in hostile
environments from overvoltage transients.
The series provides a 200A 10/1000 s rated surface
mount solution that enables equipment to comply with
enhanced surge requirments now specified in regulatory
and customer requirements.
High Surge Current Series - DO-214
Electrical Characteristics
Description
Features and Benefits
Low voltage overshoott
Low on-state voltaget
Does not degrade with t
use
Fails short circuit when t
surged in excess of
ratings
200A 10x1000 Surge t
Rating
1000A 2x10 Surge t
Rating
Agency Approvals
Agency Agency File Number
E133083
Schematic Symbol
Pinout Designation
Part Number Marking
V
DRM
@l
DRM
=5μA
V
S
@100V/μs
I
H
I
S
I
T**
V
T
@I
T
=2.2A
Capacitance
@1MHz, 2V bias
V min V max mA min mA max A max V max pf min pF max
P0080SDLRP P-8D 6 25 50 800 2.2 4 50 150
P0640SDLRP P06D 58 77 50 800 2.2 4 100 160
P0720SDLRP P07D 65 88 50 800 2.2 4 100 150
P0900SDLRP P09D 75 98 50 800 2.2 4 95 140
P1100SDLRP P11D 90 130 50 800 2.2 4 75 115
P1300SDLRP P13D 120 160 50 800 2.2 4 65 100
P1500SDLRP P15D 140 180 50 800 2.2 4 60 90
P1800SDLRP P18D 170 220 50 800 2.2 4 50 90
P2300SDLRP P23D 190 260 50 800 2.2 4 50 80
P2600SDLRP P26D 220 300 50 800 2.2 4 50 75
P3100SDLRP P31D 275 350 50 800 2.2 4 45 70
P3500SDLRP P35D 320 400 50 800 2.2 4 45 65
Applicable Global Standards
TIA-968-At
ITU K.20/21 Enhanced t
Level
ITU K.20/21 Basic Levelt
GR 1089 Inter-buildingt
GR 1089 Intra-buildingt
IEC 61000-4-5t
YD/T 1082t
YD/T 993t
YD/T 950t
Not Applicable
Notes:
- Absolute maximum ratings measured at T
A
= 25ºC (unless otherwise noted).
- Devices are uni-directional
** Will meet 4.4A power cross requirement without fire hazard.