VMS-81-36

cui.com
date 07/19/2013
page 1 of 4
SERIES: VMS-81 DESCRIPTION: AC-DC POWER SUPPLY
MODEL
output
voltage
output
current
output
power
ripple
and noise
1
ef ciency
2
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VMS-81-5 5 14.0 70 50 74
VMS-81-7 7 11.43 80 70 79
VMS-81-9 9 8.89 80 90 81
VMS-81-12 12 6.66 80 120 81
VMS-81-15 15 5.33 80 150 81
VMS-81-18 18 4.44 80 180 82
VMS-81-24 24 3.33 80 240 82
VMS-81-30 30 2.66 80 300 81
VMS-81-36 36 2.22 80 360 81
Notes: 1. Measured at full load, 90 Vac, 20MHz.
2. Measured at full load, 230 Vac. Up to 85% max.
PART NUMBER KEY
VMS-81 - XX - X
Base Number
Output Voltage Output Connector
“blank” = Molex
1 = Terminal Block
FEATURES
• up to 80 W continuous power
• universal input (90~260 Vac)
• single output from 5~36 V
• input to output 2MOPP
• active power factor correction
• over voltage and over current protections
• full medical safety approvals
• efficiency up to 85%
RoHS
®
IEC
60601-1
EN
60601-1
For more information, please visit the product page.
cui.com
date 07/19/2013 page 2 of 4
CUI Inc SERIES: VMS-81 DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90 260 Vac
frequency 47 63 Hz
input current
at 100 Vac, full load
at 240 Vac, full load
1.2
0.4
A
A
inrush current
at 115 Vac, full load, cool start at 25 °C
at 230 Vac, full load, cool start at 25 °C
28
56
A
A
leakage current at 240 Vac/60 Hz 0.1 mA
power factor correction at 240 Vac, full load 0.95 1
no load power consumption at 230 Vac 0.5 W
OUTPUT
parameter conditions/description min typ max units
line regulation full load ±1 %
load regulation at 230 Vac ±5 %
hold-up time at 110 Vac, full load 16 ms
start-up time at 100 Vac, full load 0.3 2 s
temperature coef cient ±0.4 %/°C
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection recovers automatically 112 132 %
over current protection recovers automatically 110 150 %
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage
input to output (for 1 minute, 10mA)
input to ground (for 1 minute, 10mA)
6,653
2,121
Vdc
Vdc
isolation resistance at 500 Vdc 50 MΩ
safety approvals IEC 60601-1, EN 60601-1, UL 60601-1
conducted emissions EN60601-1-2/EN55011 class B
radiated emissions EN60601-1-2/EN55011 class B
harmonics EN61000-3-2 class D
ESD IEC61000-4-2, contact ± 6kV/ air ± 8kV
radiated immunity IEC61000-4-(2, 3, 4, 5, 6, 8, 11)
EFT/burst IEC61000-4-4, ± 2kV
surge IEC61000-4-5 line to line: ± 1kV, line to earth: ± 2kV
voltage dips & interruptions IEC61000-3-3, IEC61000-4-11
MTBF MIL-HDBK-217F, at 25°C 100,000 hours
RoHS compliant yes
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature see derating curve 0 70 °C
storage temperature -40 85 °C
operating humidity 095%
storage humidity 095%
operating altitude 3000 m
For more information, please visit the product page.
cui.com
date 07/19/2013 page 3 of 4
CUI Inc SERIES: VMS-81 DESCRIPTION: AC-DC POWER SUPPLY
CN1 MATES
WITH MOLEX
HOUSING
09-50-3031 AND
MOLEX 2478
SERIES CRIMP
TERMINAL
CN2 MATES WITH
MOLEX HOUSING
09-50-3121 AND
MOLEX 2478
SERIES CRIMP
TERMINAL
CN2 TERMINAL
BLOCK 16-22AWG
MECHANICAL DRAWING
units: mm[inches]
CN2
1-Vo
2-Vo
3-Vo
4-Vo
5-Vo
6-Vo
7+Vo
8+Vo
9+Vo
10 +Vo
11 +Vo
12 +Vo
CN2
1-Vo
2-Vo
3-Vo
4+Vo
5+Vo
6+Vo
CN1
1 AC Line
2 No pin
3 AC Neutral
100
80
60
40
20
Ambient Temperature (°C)
Load (%)
010203040506070
50
Safe operating area
Temperature Derating Curve
DERATING CURVES
Optional
For more information, please visit the product page.

VMS-81-36

Mfr. #:
Manufacturer:
Description:
Switching Power Supplies ac-dc, 80 W, 36 Vdc, single output, open PCB, MED
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union