DocID022064 Rev 3 3/10
SMC30J Characteristics
10
Table 3. Electrical characteristics - parameter values (T
amb
= 25 °C)
Order code
I
RM
max@V
RM
V
BR
@I
R
(1)
V
CL
@I
PP
10/1000 µs
R
D
(2)
10/1000 µs
αT
(3)
min typ max max
µA V V mA V A
(4)
Ω 10-4/ °C
SMC30J5.0A/CA 500 5 6.4 6.74 10 9.2 327 0.008 5.7
SMC30J6.0A/CA 500 6 6.7 7.05 10 10.3 291 0.011 5.9
SMC30J6.5A/CA 250 6.5 7.2 7.58 10 11.2 268 0.014 6.1
SMC30J8.5A/CA 10 8.5 9.4 9.9 1 14.4 208 0.022 7.3
SMC30J10A/CA 0.2 10 11.1 11.7 1 17 176 0.030 7.8
SMC30J12A/CA 0.2 12 13.3 14 1 19.9 151 0.039 8.3
SMC30J13A/CA 0.2 13 14.4 15.2 1 21.5 140 0.045 8.4
SMC30J15A/CA 0.2 15 16.7 17.6 1 24.4 123 0.055 8.8
SMC30J16A/CA 0.2 16 17.8 18.7 1 26 115 0.063 8.8
SMC30J18A/CA 0.2 18 20 21.1 1 29.2 103 0.079 9.2
SMC30J20A/CA 0.2 20 22.2 23.4 1 32.4 93 0.097 9.4
SMC30J22A/CA 0.2 22 24.4 25.7 1 35.5 85 0.115 9.6
SMC30J24A/CA 0.2 24 26.7 28.1 1 38.9 77 0.140 9.6
SMC30J26A/CA 0.2 26 28.9 30.4 1 42.1 71 0.165 9.7
SMC30J28A/CA 0.2 28 31.1 32.7 1 45.4 66 0.192 9.8
SMC30J30A/CA 0.2 30 33.3 35.1 1 48.4 62 0.215 9.9
SMC30J33A/CA 0.2 33 36.7 38.6 1 53.3 56 0.261 10.0
SMC30J36A/CA 0.2 36 40.0 42.1 1 58.1 48.41 0.331 10.0
SMC30J40A/CA 0.2 40 44.4 46.7 1 64.5 43.5 0.409 10.1
SMC30J48A/CA 0.2 48 53.2 56.0 1 76.6 38.0 0.542 10.3
1. Pulse test: t
p
< 50 ms
2. To calculate maximum clamping voltage at other surge level,use the following formula: V
CLmax
= V
CL
- R
D
x (I
PP
- I
PPappli
)
where I
PPappli
is the surge current in the application
3. To calculate V
BR
or V
CL
versus junction temperature, use the following formulas:
V
BR
@ T
J
= V
BR
@ 25°C
x (1 + αT x (T
J
– 25))
V
CL
@ T
J
= V
CL
@ 25°C
x (1 + αT x (T
J
– 25))
4. Surge capability given for both directions for unidirectional and bidirectional types.