Revision: 201304
65
Note: Rated Continuous Working Voltage (RCWV) = Power Rating x Resistance Value or Max. working voltage listed above, whichever less.
NON-INDUCTIVE STYLE
STYLE NSZ500 NSZ700 NSZ10A NSZ15A NSZ20A
Power Rating at 25°C 15W 20W
Power Rating at 40°C 5W 7W 10W
Maximum Working Voltage
Voltage Proof on Insulation 700V 1,000V
Resistance Range (Wirewound) 0.1Ω - 10Ω 0.1Ω - 20Ω 0.1Ω - 30Ω
Operating Temp. Range -55°C to +155°C
Temperature Coefcient ±300ppm/°C
Note: Special value is available on request
ELECTRICAL CHARACTERISTICS
NORMAL STYLE
STYLE SQZ500 SQZ700 SQZ10A SQZ15A SQZ20A
Power Rating at 25°C 15W 20W
Power Rating at 40°C 5W 7W 10W
Maximum Working Voltage 350V 500V
Maximum Overload Voltage 700V 1,000V
Voltage Proof on Insulation 700V 1,000V
Resistance Range (Wirewound) 0.36Ω - 200Ω 0.56Ω - 430Ω 1Ω - 560Ω 1.5Ω - 750Ω
Resistance Range (Metal Oxide
Film) 220Ω - 1MΩ 300Ω - 1MΩ 470Ω - 1MΩ 750Ω - 1MΩ 820Ω - 1MΩ
Operating Temp. Range -55°C to +155°C
Temperature Coefcient ±300ppm/°C
ENVIRONMENTAL CHARACTERISTICS
PERFORMANCE TEST TEST METHOD APPRAISE
Short Time Overload IEC 60115-1 4.13 2.5 times RCWV for 5 Sec. ±2.0%+0.05Ω
Voltage Proof on Insulation IEC 60115-1 4.7 in V-block for 60 Sec., test voltage by type By type
Temperature Coefcient IEC 60115-1 4.8 -55°C to +155°C By type
Insulation Resistance IEC 60115-1 4.6 in V-block for 60 Sec. >1,000MΩ
Solderability IEC 60115-1 4.17 235±5°C for 3±0.5 Sec. 95% Min. coverage
Solvent Resistance of Marking IEC 60115-1 4.30 IPA for 5±0.5 Min. with ultrasonic
No deterioration of
coatings and markings
Periodic-pulse Overload IEC 60115-1 4.39 4 times RCWV 10,000 cycles (1 Sec. on, 25 Sec. off) ±2.0%+0.05Ω
Damp Heat Steady State IEC 60115-1 4.24 40±2°C, 90-95% RH for 56 days, loaded with 0.1 times RCWV ±5.0%+0.05Ω
Endurance at 70°C IEC 60115-1 4.25 70±2°C at RCWV for 1,000 Hr. (1.5 Hr. on, 0.5 Hr. off) ±5.0%+0.05Ω
Temperature Cycling IEC 60115-1 4.19 -55°C Room Temp. +155°C Room Temp. (5 cycles) ±2.0%+0.05Ω
Resistance to Soldering Heat IEC 60115-1 4.18 260±3°C for 10±1 Sec., immersed to a point 3±0.5mm from the body ±1.0%+0.05Ω