5
IDT54/74FCT162511AT/CT
FAST CMOS 16-BIT REGISTERED/LATCHED TRANSCEIVER
MILITARY AND INDUSTRIAL TEMPERATURE RANGES
Symbol Parameter Test Conditions
(1)
Min. Typ.
(2)
Max. Unit
V
IH Input HIGH Level Guaranteed Logic HIGH Level 2 — — V
VIL Input LOW Level Guaranteed Logic LOW Level — — 0.8 V
I
IH Input HIGH Current (Input pins)
(5)
VCC = Max. VI = VCC —— ±1µA
Input HIGH Current (I/O pins)
(5)
—— ±1
I
IL Input LOW Current (Input pins)
(5)
VI = GND — — ±1
Input LOW Current (I/O pins)
(5)
—— ±1
I
OZH High Impedance Output Current VCC = Max. VO = 2.7V — — ±1µA
IOZL (3-State Output pins)
(5)
VO = 0.5V — — ±1
VIK Clamp Diode Voltage VCC = Min., IIN = –18mA — –0.7 –1.2 V
IOS Short Circuit Current VCC = Max., VO = GND
(3)
–80 –140 –250 mA
VH Input Hysteresis — — 100 — mV
I
CCL Quiescent Power Supply Current VCC = Max. — 5 500 µA
ICCH VIN = GND or VCC
ICCZ
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Industrial: TA = –40°C to +85°C, VCC = 5.0V ±10%; Military: TA = –55°C to +125°C, VCC = 5.0V ±10%
NOTES:
1. For conditions shown as Min. or Max., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 5.0V, +25°C ambient.
3. Not more than one output should be shorted at one time. Duration of the test should not exceed one second.
4. Duration of the condition can not exceed one second.
5. The test limit for this parameter is ±5µA at TA = –55°C.
OUTPUT DRIVE CHARACTERISTICS
Symbol Parameter Test Conditions
(1)
Min. Typ.
(2)
Max. Unit
IODL Output LOW (I/O pins) VCC = 5V, VIN = VIH or VIL, VO = 1.5V
(3)
60 115 200 mA
Current (Open Drain) — 250 — mA
IODH Output HIGH Current VCC = 5V, VIN = VIH or VIL, VO = 1.5V
(3)
–60 –115 –200 mA
I
OFF Output Power Off Leakage Current VCC = 0, VO ≤ 5.5V — — ±1 µ A
(Open Drain)
(5)
VOH Output HIGH Voltage (I/O pins) VCC = Min. IOH = –16mA MIL 2.4 3.3 — V
VIN = VIH or VIL IOH = –24mA IND
V
OL Output LOW (I/O pins) VCC = Min. IOL = 16mA MIL — 0.3 0.55 V
Voltage VIN = VIH or VIL IOL = 24mA IND
(Open Drain) I
OL = 48mA MIL — 0.3 0.55 V
I
OL = 64mA IND