MC74LVXT4053
www.onsemi.com
4
DC CHARACTERISTICS − Digital Section (Voltages Referenced to GND)
Symbol Parameter Condition
V
CC
V
Guaranteed Limit
Unit
−55 to 25°C v85°C v125°C
V
IH
Minimum High−Level Input Voltage,
Channel−Select or Enable Inputs
3.0
4.5
5.5
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
V
V
IL
Maximum Low−Level Input Voltage,
Channel−Select or Enable Inputs
3.0
4.5
5.5
0.5
0.8
0.8
0.5
0.8
0.8
0.5
0.8
0.8
V
I
IN
Maximum Input Leakage Current,
Channel−Select or Enable Inputs
V
IN
= 6.0 or GND 0 V to 6.0 V ±0.1 ±1.0 ±1.0
A
I
CC
Maximum Quiescent Supply
Current (per Package)
Channel Select, Enable and
V
IS
= V
CC
or GND
6.0 4.0 40 80
A
DC ELECTRICAL CHARACTERISTICS − Analog Section
Symbol Parameter Test Conditions
V
CC
V
V
EE
V
Guaranteed Limit
Unit
−55 to 25°C
v85_C v125_C
R
ON
Maximum “ON” Resistance V
IN
= V
IL
or V
IH
V
IS
= ½ (V
CC
− V
EE
)
|I
S
| = 2.0 mA (Figure 3)
3.0
4.5
3.0
0
0
−3.0
86
37
26
108
46
33
120
55
37
R
ON
Maximum Difference in “ON”
Resistance Between Any Two
Channels in the Same Package
V
IN
= V
IL
or V
IH
V
IS
= ½ (V
CC
− V
EE
)
|I
S
| = 2.0 mA
3.0
4.5
3.0
0
0
−3.0
15
13
10
20
18
15
20
18
15
I
off
Maximum Off−Channel Leakage
Current, Any One Channel
V
in
= V
IL
or V
IH
;
V
IO
= V
CC
or GND;
Switch Off (Figure 3)
5.5
+3.0
0
−3.0
0.1
0.1
0.5
0.5
1.0
1.0
A
Maximum Off−Channel Leakage
Current, Common Channel
V
in
= V
IL
or V
IH
;
V
IO
= V
CC
or GND;
Switch Off (Figure 4)
5.5
+3.0
0
−3.0
0.2
0.2
2.0
2.0
4.0
4.0
I
on
Maximum On−Channel Leakage
Current, Channel−to−Channel
V
in
= V
IL
or V
IH
;
Switch−to−Switch =
V
CC
or GND; (Figure 5)
5.5
+3.0
0
−3.0
0.2
0.2
2.0
2.0
4.0
4.0
A
AC CHARACTERISTICS (Input t
r
= t
f
= 3 ns)
Symbol
Parameter Test Conditions
V
CC
V
V
EE
V
Guaranteed Limit
Unit
−55 to 25_C
v85_C v125_C
Min Typ*
t
BBM
Minimum Break−Before−Make
Time
V
IN
= V
IL
or V
IH
V
IS
= V
CC
R
L
= 300 C
L
= 35 pF
(Figures 11 and 12)
3.0
4.5
3.0
0.0
0.0
−3.0
1.0
1.0
1.0
6.5
5.0
3.5
−
−
−
−
−
−
ns
*Typical Characteristics are at 25_C.