2
G3VM-61AY/DYG3VM-61AY/DY
■ Absolute Maximum Ratings (Ta = 25C)
■ Electrical Characteristics (Ta = 25C)
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
■ Engineering Data
Load Current vs. Ambient Temperature
G3VM-61AY(DY)
■ Safety Precautions
Refer to “Common Precautions” for all G3VM models.
Item Symbol Rating Unit Measurement Conditions
Input LED forward current I
F
30 mA
Repetitive peak LED forward
current
I
FP
1 A 100 s pulses, 100 pps
LED forward current reduc-
tion rate
I
F
/C 0.3 mA/CTa 25C
LED reverse voltage V
R
5V
Connection temperature T
j
125 C
Output Load voltage (AC peak/DC) V
OFF
60 V
Continuous load current (AC
peak/DC)
I
O
500 mA
ON current reduction rate I
O
/C 5.0 mA/CTa 25C
Pulse ON current I
op
1.5 A t = 100 ms, Duty = 1/10
Connection temperature T
j
125 C
Dielectric strength between input and
output (See note 1.)
V
I-O
5,000 Vrms AC for 1 min
Operating temperature T
a
40 to +85 C With no icing or condensation
Storage temperature T
stg
55 to +125 C With no icing or condensation
Soldering temperature (10 s) --- 260 C 10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Item Symbol Mini-
mum
Typical Maxi-
mum
Unit Measurement
conditions
Input LED forward voltage V
F
1.45 1.63 1.75 V I
F
= 10 mA
Reverse current I
R
--- --- 10 AV
R
= 5 V
Capacity between terminals C
T
--- 40 --- pF V = 0, f = 1 MHz
Trigger LED forward current I
FT
--- 0.3 2 mA I
O
= 500 mA
Output Maximum resistance with output ON R
ON
--- 0.6 2 I
F
= 5 mA,
I
O
= 500 mA
Current leakage when the relay is
open
I
LEAK
--- --- 1.0 AV
OFF
= 60 V
Capacity between terminals C
OFF
--- 130 --- pF V = 0, f = 1 MHz
Capacity between I/O terminals C
I-O
--- 0.8 --- pF f = 1 MHz, Vs = 0 V
Insulation resistance R
I-O
1,000 --- --- M V
I-O
= 500 VDC,
RoH 60%
Turn-ON time tON --- 0.5 1 ms I
F
= 5 mA, R
L
= 200
V
DD
= 20 V (See note 2.)
Turn-OFF time tOFF --- 0.2 1 ms
10%
90%
VOUT
IF
t
ON
t
OFF
I
F
1
2
4
3
R
L
V
DD
V
OUT
Note: 2. Turn-ON and Turn-OFF
Times
Item Symbol Minimum Typical Maximum Unit
Load voltage (AC peak/DC) V
DD
--- --- 48 V
Operating LED forward current I
F
3515mA
Continuous load current (AC peak/DC) I
O
--- --- 500 mA
Operating temperature T
a
20 --- 65 C
Ambient temperature (°C)
Load current (mA)
600
500
400
300
200
100
0
−20 0 20 40 60 80 100