ADuM1234 Data Sheet
Rev. A | Page 6 of 12
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 7.
Parameter Rating
Storage Temperature (T
ST
) −55°C to +150°C
Ambient Operating Temperature (T
A
) −40°C to +105°C
Input Supply Voltage
1
(V
DD1
) −0.5 V to +7.0 V
Output Supply Voltage
1
(V
DDA
, V
DDB
) −0.5 V to +27 V
Input Voltage
1
(V
IA
, V
IB
) −0.5 V to V
DD1
+ 0.5 V
Output Voltage
1
OA
DDA
V
OB
−0.5 V to V
DDB
+ 0.5 V
Input-to-Output Voltage
2
−700 V peak to +700 V peak
Output Differential Voltage
3
700 V peak
Output DC Current (I
OA
, I
OB
) −20 mA to +20 mA
Common-Mode Transients
4
−100 kV/µs to +100 kV/µs
1
All voltages are relative to their respective grounds.
2
Input-to-output voltage is defined as GND
A
− GND
1
or GND
B
− GND
1
.
3
Output differential voltage is defined as GND
A
− GND
B
.
4
Refers to common-mode transients across any insulation barrier. Common-
mode transients exceeding the absolute maximum ratings may cause latch-up
or permanent damage.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
Table 8. Maximum Continuous Working Voltage
1
Parameter Max Unit Constraint
AC Voltage, Bipolar Waveform 560 V peak 50-year minimum lifetime
AC Voltage, Unipolar Waveform
Basic Insulation 700 V peak Analog Devices recommended maximum working voltage
DC Voltage
Basic Insulation 700 V peak Analog Devices recommended maximum working voltage
1
Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more information.