DATA SHEET • AV113-12LF: HIP3™ VARIABLE ATTENUATOR
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2 August 29, 2014 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 200263C
Electrical and Mechanical Specifications
The absolute maximum ratings for the AV113-12LF are shown in
Table 1. Electrical specifications are provided in Table 2, and
operating characteristics are shown in Table 3.
Typical performance characteristics are shown in Figures 3
through 6.
Table 1. AV113-12LF Absolute Maximum Ratings (Note 1)
Parameter Symbol Minimum Maximum Units
RF input power 0.5 W CW, 4 W @
12.5% duty cycle
Control current 50 mA per diode mA
Operating temperature T
A
–40 +85 C
Storage temperature T
STG
–65 +150 C
Maximum reverse diode voltage –10 V
Electrostatic discharge:
Human Body Model (HBM), Class 0
ESD
125
V
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 2. AV113-12LF Electrical Specifications (Note 1)
(TOP = 25 °C, Unless Otherwise Noted)
Parameter Minimum Typical Maximum Units
Frequency 2.1 2.3 GHz
Insertion loss (0 mA control current) 1.4 1.6 dB
Attenuation @ 1.0 mA control current 16.5 18 dB
VSWR all ports 1.5
Input 3rd order intercept point +40 dBm
Group delay 0.4 0.8 ns
Note 1: Performance is guaranteed only under the conditions defined in this table.
Table 3. AV113-12LF Operating Characteristics (Note 1)
(TOP = 25 °C, 0 V, 5 V,Unless Otherwise Noted)
Parameter Condition Minimum Typical Maximum Units
Switching characteristics (Note 2):
Rise, fall
On, off
Video feedthru (peak)
10/90% or 90/10% RF
50% CTL to 90/10% RF
5
8
2
μs
μs
mV
Maximum input power for <1 dB
attenuation variation
+15
dBm
Note 1: All measurements made in a 50 Ω system, unless otherwise specified.
Note 2: 0 to 4 mA square wave total control current.