NL17SG126
http://onsemi.com
5
AC ELECTRICAL CHARACTERISTICS (Input t
r
= t
f
= 3.0 ns) (continued)
Symbol Unit
T
A
=
−555C to +1255C
T
A
= 25 5C
V
CC
(V)Test ConditionParameterSymbol UnitMaxMinMaxTypMinV
CC
(V)Test ConditionParameterSymbol UnitMaxMinMaxTypMinV
CC
(V)Test ConditionParameter
t
PHZ
,
t
PLZ
Output Disable Time,
OE
to Y
C
L
= 10 pF;
ns
R
L
= 100 kW
0.9 − 100.4 − − −
R
L
= 5 kW
1.1 to 1.3 − 9.1 14.4 − 22.4
R
L
= 5 kW
1.4 to 1.6 − 7.1 9.1 − 10.4
R
L
= 5 kW
1.65 to 1.95 − 6.5 8.3 − 9
R
L
= 5 kW
2.3 to 2.7 − 5.8 7.3 − 8.8
R
L
= 5 kW
3.0 to 3.6 − 5.4 6.9 − 7.6
C
L
= 15 pF;
ns
R
L
= 100 kW
0.9 − 122.2 − − −
R
L
= 5 kW
1.1 to 1.3 − 9.8 15.3 − 25.1
R
L
= 5 kW
1.4 to 1.6 − 7.8 9.8 − 11.3
R
L
= 5 kW
1.65 to 1.95 − 7.2 9.2 − 10.6
R
L
= 5 kW
2.3 to 2.7 − 7 8.2 − 10.3
R
L
= 5 kW
3.0 to 3.6 − 6.6 7.7 − 9.5
C
L
= 30 pF;
ns
R
L
= 100 kW
0.9 − 217.1 − − −
R
L
= 5 kW
1.1 to 1.3 − 13.2 19.6 − 31.9
R
L
= 5 kW
1.4 to 1.6 − 12.2 13.5 − 14.9
R
L
= 5 kW
1.65 to 1.95 − 11.4 12.7 − 13.9
R
L
= 5 kW
2.3 to 2.7 − 11.3 12.2 − 13.5
R
L
= 5 kW
3.0 to 3.6 − 10.2 11.5 − 12.9
C
IN
Input Capacitance 0 to 3.6 3 − − − pF
C
O
Output Capacitance V
O
= GND 0 3 − − − pF
C
PD
Power Dissipation
Capacitance (Note 5)
f = 10 MHz 0.9 to 3.6 − 4 − − − pF
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
5. C
PD
is defined as the value of the internal equivalent capacitance which is calculated from the operating current consumption without load.
Average operating current can be obtained by the equation: I
CC(OPR
)
= C
PD
V
CC
f
in
+ I
CC
. C
PD
is used to determine the no−load dynamic
power consumption; P
D
= C
PD
V
CC
2
f
in
+ I
CC
V
CC
.