Nexperia
74AXP1T14
Dual supply Schmitt trigger inverter
74AXP1T14 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 2 — 9 May 2017
4 / 17
Symbol Parameter Conditions Min Max Unit
P
tot
total power dissipation T
amb
= -40 °C to +85 °C - 250 mW
[1] The minimum input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] V
CCO
+ 0.5 V should not exceed 6.0 V.
9 Recommended operating conditions
Table 6. Recommended operating conditions
Voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions Min Max Unit
V
CCI
input supply voltage 0.7 2.75 V
V
CCO
output supply voltage 1.2 5.5 V
V
I
input voltage 0 2.75 V
Active mode 0 V
CCO
VV
O
output voltage
Power-down or 3-state mode 0 5.5 V
T
amb
ambient temperature -40 +85 °C
10 Static characteristics
Table 7. Static characteristics
At recommended operating conditions, unless otherwise specified; voltages are referenced to GND (ground = 0 V).
T
amb
= -40 °C to +85 °CSymbol Parameter Conditions
Min Typ
25 °C
Max
25 °C
Max
85 °C
Unit
see Figure 5 and Figure 6
V
CCI
= 0.75 V to 0.85 V 0.3V
CCI
- 0.8V
CCI
0.8V
CCI
V
V
CCI
= 1.1 V to 1.95 V 0.4V
CCI
- 0.7V
CCI
0.7V
CCI
V
V
T+
positive-going
threshold voltage
V
CCI
= 2.3 V to 2.7 V 0.9 - 1.7 1.7 V
see Figure 5 and Figure 6
V
CCI
= 0.75 V to 0.85 V 0.2V
CCI
- 0.7V
CCI
0.7V
CCI
V
V
CCI
= 1.1 V to 1.95 V 0.3V
CCI
- 0.6V
CCI
0.6V
CCI
V
V
T-
negative-going
threshold voltage
V
CCI
= 2.3 V to 2.7 V 0.7 - 1.5 1.5 V
see Figure 5 and Figure 6
V
CCI
= 0.75 V to 0.85 V 0.06V
CCI
- 0.5V
CCI
0.5V
CCI
V
V
CCI
= 1.1 V to 1.95 V 0.1V
CCI
- 0.4V
CCI
0.4V
CCI
V
V
H
hysteresis voltage
V
CCI
= 2.3 V to 2.7 V 0.2 - 1.0 1.0 V
I
O
= -2 mA; V
CCO
= 1.2 V
[1]
- 1.05 - - V
I
O
= -3 mA; V
CCO
= 1.4 V 1.05 - - - V
I
O
= -4.5 mA; V
CCO
= 1.65 V 1.2 - - - V
V
OH
HIGH-level output
voltage
I