Nexperia
74AXP1T14
Dual supply Schmitt trigger inverter
74AXP1T14 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 2 — 9 May 2017
4 / 17
Symbol Parameter Conditions Min Max Unit
P
tot
total power dissipation T
amb
= -40 °C to +85 °C - 250 mW
[1] The minimum input and output voltage ratings may be exceeded if the input and output current ratings are observed.
[2] V
CCO
+ 0.5 V should not exceed 6.0 V.
9 Recommended operating conditions
Table 6. Recommended operating conditions
Voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions Min Max Unit
V
CCI
input supply voltage 0.7 2.75 V
V
CCO
output supply voltage 1.2 5.5 V
V
I
input voltage 0 2.75 V
Active mode 0 V
CCO
VV
O
output voltage
Power-down or 3-state mode 0 5.5 V
T
amb
ambient temperature -40 +85 °C
10 Static characteristics
Table 7. Static characteristics
At recommended operating conditions, unless otherwise specified; voltages are referenced to GND (ground = 0 V).
T
amb
= -40 °C to +85 °CSymbol Parameter Conditions
Min Typ
25 °C
Max
25 °C
Max
85 °C
Unit
see Figure 5 and Figure 6
V
CCI
= 0.75 V to 0.85 V 0.3V
CCI
- 0.8V
CCI
0.8V
CCI
V
V
CCI
= 1.1 V to 1.95 V 0.4V
CCI
- 0.7V
CCI
0.7V
CCI
V
V
T+
positive-going
threshold voltage
V
CCI
= 2.3 V to 2.7 V 0.9 - 1.7 1.7 V
see Figure 5 and Figure 6
V
CCI
= 0.75 V to 0.85 V 0.2V
CCI
- 0.7V
CCI
0.7V
CCI
V
V
CCI
= 1.1 V to 1.95 V 0.3V
CCI
- 0.6V
CCI
0.6V
CCI
V
V
T-
negative-going
threshold voltage
V
CCI
= 2.3 V to 2.7 V 0.7 - 1.5 1.5 V
see Figure 5 and Figure 6
V
CCI
= 0.75 V to 0.85 V 0.06V
CCI
- 0.5V
CCI
0.5V
CCI
V
V
CCI
= 1.1 V to 1.95 V 0.1V
CCI
- 0.4V
CCI
0.4V
CCI
V
V
H
hysteresis voltage
V
CCI
= 2.3 V to 2.7 V 0.2 - 1.0 1.0 V
I
O
= -2 mA; V
CCO
= 1.2 V
[1]
- 1.05 - - V
I
O
= -3 mA; V
CCO
= 1.4 V 1.05 - - - V
I
O
= -4.5 mA; V
CCO
= 1.65 V 1.2 - - - V
V
OH
HIGH-level output
voltage
I
O
= -8 mA; V
CCO
= 2.3 V 1.7 - - - V
Nexperia
74AXP1T14
Dual supply Schmitt trigger inverter
74AXP1T14 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 2 — 9 May 2017
5 / 17
T
amb
= -40 °C to +85 °CSymbol Parameter Conditions
Min Typ
25 °C
Max
25 °C
Max
85 °C
Unit
I
O
= -10 mA; V
CCO
= 3.0 V 2.2 - - - V
I
O
= -12 mA; V
CCO
= 4.5 V 3.7 - - - V
I
O
= 2 mA; V
CCO
= 1.2 V
[1]
- 0.18 - - V
I
O
= 3 mA; V
CCO
= 1.4 V - - 0.35 0.35 V
I
O
= 4.5 mA; V
CCO
= 1.65 V - - 0.45 0.45 V
I
O
= 8 mA; V
CCO
= 2.3 V - - 0.7 0.7 V
I
O
= 10 mA; V
CCO
= 3.0 V - - 0.8 0.8 V
V
OL
LOW-level output
voltage
I
O
= 12 mA; V
CCO
= 4.5 V - - 0.8 0.8 V
I
I
input leakage
current
V
I
= 0 V to 2.75 V;
V
CCI
= 0 V to 2.75 V
[1]
- ±0.001 ±0.1 ±0.5 μA
I
OZ
OFF-state output
current
V
O
= 0 V to 5.5 V;
V
CCO
= 1.2 V to 5.5 V
- ±0.001 ±0.1 ±0.5 μA
inputs; V
I
= 0 V to 2.75 V;
V
CCI
= 0 V;
V
CCO
= 0 V to 5.5 V
[1]
- ±0.01 ±0.1 ±0.5 μAI
OFF
power-off leakage
current
output; V
O
= 0 V to 5.5 V;
V
CCO
= 0 V;
V
CCI
= 0 V to 2.75 V;
V
I
= 0 V to 2.75 V
[1]
- ±0.01 ±0.1 ±0.5 μA
inputs; V
I
= 0 V or 2.75 V;
V
CCI
= 0 V to 0.1 V;
V
CCO
= 0 V to 5.5 V
[1]
- ±0.02 ±0.1 ±0.5 μAΔI
OFF
additional
power-off leakage
current
output; V
O
= 0 V or 5.5 V;
V
CCO
= 0 V to 0.1 V;
V
CCI
= 0 V to 2.75 V;
V
I
= 0 V or 2.75 V
[1]
- ±0.02 ±0.1 ±0.5 μA
[1] Typical values are measured at V
CCI
= V
CCO
= 1.2 V unless otherwise specified.
mna207
V
O
V
I
V
H
V
T+
V
T-
Figure 5. Transfer characteristic
mna208
V
O
V
I
V
H
V
T+
V
T-
Figure 6. Definition of V
T+
, V
T-
, and V
H
Nexperia
74AXP1T14
Dual supply Schmitt trigger inverter
74AXP1T14 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 2 — 9 May 2017
6 / 17
Table 8. Static characteristics supply current
At recommended operating conditions, unless otherwise specified; voltages are referenced to GND (ground = 0 V).
T
amb
= -40 °C to +85 °CSymbol Parameter Conditions
Typ
25 °C
Max
25 °C
Typ
85 °C
Max
85 °C
Unit
V
I
= 0 V or V
CCI
;
V
CCI
= 0.7 V to 1.3 V
[1]
1 100 10 300 nA
V
CCI
= 1.3 V to 2.75 V
[2]
1 100 20 500 nA
V
CCI
= 2.75 V; V
CCO
= 0 V 1 100 20 500 nA
I
CCI
input supply
current
V
CCI
= 0 V; V
CCO
= 5.5 V 1 100 1 100 nA
V
I
= 0 V or V
CCI
; I
O
= 0 A;
see Table 9
V
CCO
= 1.2 V to 3.6 V
[1]
0.001 1.0 0.01 1.2 μA
V
CCO
= 3.6 V to 5.5 V
[3]
0.8 1.5 1.0 1.8 μA
V
CCI
= 2.75 V; V
CCO
= 0 V 0.001 0.1 0.003 0.2 μA
V
CCI
= 0 V; V
CCO
= 3.6 V 0.2 0.6 0.3 0.8 μA
I
CCO
output supply
current
V
CCI
= 0 V; V
CCO
= 5.5 V 0.4 0.8 0.5 1.0 μA
ΔI
CCI
additional input
supply current
V
I
= V
CCI
- 0.5 V; V
CCI
= 2.5 V 2 100 14 150 μA
[1] Typical values are measured at V
CCI
= V
CCO
= 1.2 V unless otherwise specified.
[2] Typical values are measured at V
CCI
= V
CCO
= 2.5 V.
[3] Typical values are measured at V
CCI
= 1.2 V and V
CCO
= 5.0 V.
Table 9. Typical output supply current (I
CCO
)
V
CCO
V
CCI
0 V 1.2 V 1.5 V 1.8 V 2.5 V 3.3 V 5.0 V
Unit
0 V 0 1 5 20 100 200 400 nA
0.8 V 1 10 150 200 300 500 800 nA
1.2 V 1 1 5 200 300 500 800 nA
1.5 V 1 1 5 100 300 500 800 nA
1.8 V 1 1 5 100 300 500 800 nA
2.5 V 1 1 5 100 100 500 800 nA

74AXP1T14GXH

Mfr. #:
Manufacturer:
Nexperia
Description:
Dual supply Schmitt trigger inverte
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet