MDC3105
www.onsemi.com
7
Figure 11. Zener Repetitive Pulse Energy Limit
on L/R Time Constant for MDC3105LT1
0.001
Izpk (AMPS)
100
10
MAX L/R TIME CONSTANT (ms)
0.01 1.
0
1.0 k
10 k
100 k
0.1
T
A
= 25°C
E
max
= 50 mJ
L/R = 2 * E
max
÷ (Vzpk * Izpk)
t1, PULSE WIDTH (ms)
r(t), TRANSIENT THERMAL
RESISTANCE (NORMALIZED)
1.0
0.1
0.01
0.01 0.1 1.0 10 100 1000 10,000 100,000 1,000,000
0.001
Figure 12. Transient Thermal Response for MDC3105LT1
D = 0.5
0.2
0.1
0.05
0.02
SINGLE PULSE
0.01
P
d(pk)
t
1
t
2
DUTY CYCLE = t
1
/t
2
PERIOD
PW
MDC3105
www.onsemi.com
8
Using TTR Designing for Pulsed Operation
For a repetitive pulse operating condition, time averaging
allows one to increase a device’s peak power dissipation
rating above the average rating by dividing by the duty cycle
of the repetitive pulse train. Thus, a continuous rating of 200
mW of dissipation is increased to 1.0 W peak for a 20% duty
cycle pulse train. However, this only holds true for pulse
widths which are short compared to the thermal time
constant of the semiconductor device to which they are
applied.
For pulse widths which are significant compared to the
thermal time constant of the device, the peak operating
condition begins to look more like a continuous duty
operating condition over the time duration of the pulse. In
these cases, the peak power dissipation rating cannot be
merely time averaged by dividing the continuous power
rating by the duty cycle of the pulse train. Instead, the
average power rating can only be scaled up a reduced
amount in accordance with the device’s transient thermal
response, so that the device’s max junction temperature is
not exceeded.
Figure 12 of the MDC3105 data sheet plots its transient
thermal resistance, r(t) as a function of pulse width in ms for
various pulse train duty cycles as well as for a single pulse
and illustrates this effect. For short pulse widths near the left
side of the chart, r(t), the factor, by which the continuous
duty thermal resistance is multiplied to determine how much
the peak power rating can be increased above the average
power rating, approaches the duty cycle of the pulse train,
which is the expected value. However, as the pulse width is
increased, that factor eventually approaches 1.0 for all duty
cycles indicating that the pulse width is sufficiently long to
appear as a continuous duty condition to this device. For the
MDC3105LT1, this pulse width is about 100 seconds. At
this and larger pulse widths, the peak power dissipation
capability is the same as the continuous duty power
capability.
To use Figure 12 to determine the peak power rating for
a specific application, enter the chart with the worst case
pulse condition, that is the max pulse width and max duty
cycle and determine the worst case r(t) for your application.
Then calculate the peak power dissipation allowed by using
the equation,
Pd(pk) = (T
Jmax
− T
Amax
) ÷ (R
q
JA
* r(t))
Pd(pk) = (150°C
− T
Amax
) ÷ (556°C/W * r(t))
Thus for a 20% duty cycle and a PW = 40 ms, Figure 12
yields r(t) = 0.3 and when entered in the above equation, the
max allowable Pd(pk) = 390 mW for a max T
A
= 85°C.
Also note that these calculations assume a rectangular
pulse shape for which the rise and fall times are insignificant
compared to the pulse width. If this is not the case in a
specific application, then the V
O
and I
O
waveforms should
be multiplied together and the resulting power waveform
integrated to find the total dissipation across the device. This
then would be the number that has to be less than or equal to
the Pd(pk) calculated above. A circuit simulator having a
waveform calculator may prove very useful for this purpose.
Notes on SOA and Time Constant Limitations
Figure 10 is the Safe Operating Area (SOA) for the
MDC3105. Device instantaneous operation should never be
pushed beyond these limits. It shows the SOA for the
Transistor “ON” condition as well as the SOA for the Zener
during the turn−off transient. The max current is limited by
the Izpk capability of the Zener as well as the transistor in
addition to the max input current through the resistor. It
should not be exceeded at any temperature. The BJT power
dissipation limits are shown for various pulse widths and
duty cycles at an ambient temperature of 25°C. The voltage
limit is the max V
CC
that can be applied to the device. When
the input to the device is switched off, the BJT “ON” current
is instantaneously dumped into the Zener diode where it
begins its exponential decay. The Zener clamp voltage is a
function of that BJT current level as can be seen by the
bowing of the V
Z
versus I
Z
curve at the higher currents. In
addition to the Zeners current limit impacting this device’s
500 mA max rating, the clamping diode also has a peak
energy limit as well. This energy limit was measured using
a rectangular pulse and then translated to an exponential
equivalent using the 2:1 relationship between the L/R time
constant of an exponential pulse and the pulse width of a
rectangular pulse having equal energy content. These L/R
time constant limits in ms appear along the V
Z
versus I
Z
curve for the various values of I
Z
at which the Pd lines
intersect the V
CC
limit. The L/R time constant for a given
load should not exceed these limits at their respective
currents. Precise L/R limits on Zener energy at intermediate
current levels can be obtained from Figure 11.
MDC3105
www.onsemi.com
9
Designing with this Data Sheet
1. Determine the maximum inductive load current (at
max V
CC
, min coil resistance and usually minimum
temperature) that the MDC3105 will have to drive
and make sure it is less than the max rated current.
2. For pulsed operation, use the Transient Thermal
Response of Figure 12 and the instructions with it
to determine the maximum limit on transistor power
dissipation for the desired duty cycle and
temperature range.
3. Use Figures 10 and 11 with the SOA notes above to
insure that instantaneous operation does not push
the device beyond the limits of the SOA plot.
4. While keeping any V
O(sat)
requirements in mind,
determine the max input current needed to achieve
that output current from Figures 2 and 6.
5. For levels of input current below 100 mA, use the
input threshold curves of Figure 4 to verify that
there will be adequate input current available to turn
on the MDC3105 at all temperatures.
6. For levels of input current above 100 mA, enter
Figure 3 using that max input current and determine
the input voltage required to drive the MDC3105
from the solid V
in
versus I
in
line. Select a suitable
drive source family from those whose dotted lines
cross the solid input characteristic line to the right
of the I
in
, V
in
point.
7. Using the max output current calculated in step 1,
check Figure 7 to insure that the range of Zener
clamp voltage over temperature will satisfy all
system and EMI requirements.
8. Using Figures 8 and 9, insure that “OFF” state
leakage over temperature and voltage extremes does
not violate any system requirements.
9. Review circuit operation and insure none of the
device max ratings are being exceeded.
Figure 13. A 200 mW, 5.0 V Dual Coil Latching Relay Application
with 3.0 V−HCMOS Level Translating Interface
+4.5 V
CC
+5.5 Vdc
+
V
out
(6)
74HC04 OR
EQUIVALENT
+
AROMAT
TX2-L2-5 V
V
in
(5)
GND (1)
V
out
(3)
V
in
(2)
GND (4)
74HC04 OR
EQUIVALENT
MDC3105DMT1
+3.0 V
DD
+3.75 Vdc