SXE15-48S3V3-R

2 YEAR WARRANTY
SXE15 Series
Single output
High efficiency topology, 87% typical at 5 V
Wide operating temperature, up to and exceeding 70 ˚C
(natural convection)
90% to 110% output trim
No minimum load
Overvoltage protection
Remote ON/OFF control
Available RoHS compliant
The SXE15 is a new high efficiency open frame isolated 15 Watt converter series in
an industry standard footprint. All models in the series feature an input voltage range
of 33 Vdc to 75 Vdc and are available in output voltages of 12 V, 5 V, 3.3 V, 2.5 V
and 1.8 V. The output voltage on each model is adjustable from 90% to 110% of the
nominal value. Typical efficiencies for the models are 87% for the 5 V, 86% for the
3.3 V, 85% for the 2.5 V and 12 V and 83% for the 1.8 V version. The SXE15 series
also has a remote ON/OFF capability with active high or active low logic.
Overcurrent and overvoltage protection features are included as standard. With full
international safety approval including EN60950 and cUL1950, the SXE15 reduces
compliance costs and time to market.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
OUTPUT SPECIFICATIONS
Voltage adjustability 90% to 110%
Total error band (See Note 13) ±4% max.
Line regulation 1.8 V and 2.5 V models 0.5% max.
Low line to high line 3.3 V and 5 V models 0.1% max.
Load regulation 1.8 V model 2.0% max.
Full load to min. load 2.5 V model 1.5% max.
3.3 V and 5 V models 0.5% max.
Minimum load (See Note 12) 0%
Overshoot 1.8 V and 2.5 V models 4% max.
At turn-on and turn-off 3.3 V and 5 V models None
Undershoot None
Ripple and noise 1.8 V and 2.5 V models 40 mV pk-pk
(See Note 1) 14 mV rms
5 Hz to 20 MHz 3.3 V and 5 V models 70 mV pk-p
20 mV rms
Transient response 1.8 V and 2.5 V models 150 mV
(See Note 2) 3.3 V and 5 V models 100 mV
Typical deviation 400 µs recovery to
within total error band
INPUT SPECIFICATIONS
Input voltage range 48 Vin nominal 33-75 Vdc
Input current No load 35 mA max.
Remote OFF 25 mA max.
Input current (max.) (See Note 4) 0.55 A max. @ Io max.
and Vin = 33-75 Vdc
Input reflected ripple (See Note 6) 5 mA (pk-pk) typ.
Active high remote ON/OFF (See Note 8)
Logic compatibility Open collector ref to -input
ON Open circuit or >2 Vdc
OFF <1.2 Vdc
Undervoltage lockout Power up 33 V (typ.)
Power down 30 V (typ.)
Start-up time Power up 1.5 ms (typ.)
(See Note 7) Remote ON/OFF 2.5 ms (typ.)
SPECIFICATIONS
File Name: sxe15s.pdf Rev (02): 08 Dec 2005
EMC CHARACTERISTICS
Conducted emissions
EN55022 (See Note 3)
Level A
EN55022 (See Note 3)
Level B
Radiated emissions
EN55022 (See Longform Datasheet)
Level B
Immunity:
ESD air EN61000-4-2 8 kV, 15 kV
ESD contact EN61000-4-2 6 kV, 8 kV
Radiated field enclosure EN61000-4-3 10 V/m
Conducted (dc power) EN61000-4-6 10 V
Conducted (signal) EN61000-4-6 10 V (See Note 11)
Input transients ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency See table
Operational insulation Input/output 1500 Vdc
Switching frequency Fixed 265 kHz typ.
Approvals and UL/cUL1950, EN60950
standards (See Notes 5) TÜV Rheinland
Material flammability UL94V-0
Weight 12 g (0.42 oz)
Coplanarity 150 µm
MTBF MIL-HDBK-217F 1,790,000 hours
Representative model: 48S05J @ 48 Vin, 40 °C,
100% load ground benign
BELLCORE 332 >1,500,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient -40 °C to +65 °C
(See Note 9) temp. (3.3 V and 5 V)
Operating ambient -40 °C to +70 °C
temp. (1.8 V, 2.5 V
and 12 V)
Non-operating -40 °C to +120 °C
(All models)
TÜV
Tolerence: ±.015 (±.38)
Recommended Land & Hole Pattern
1.575 (40.01)
0.197 (5.00)
0.394 (10.01)
ø0.063 (ø1.60)
1.200 (30.48)
0.161 (4.09)
0.125 (3.18)
1.812 (46.02)
0.130 (3.30)
0.047 (1.18)
1.812 (46.02)
1.575 (40.01)
1.885 (47.88)
0.070 (1.78) MAX
1.812 (46.03)
0.335 (8.51) MAX
0.010 (0.25) MIN
1.905 (48.39)
1.390 (35.31)
1.150 (29.21)
leadframe length
overall length
BOTTOM VIEW
SIDE VIEW
TOP VIEW
ø.050 (ø1.27)
Non-Skid Retaining Pins,
2 Places
1
0.477 (12.11)
0.502 (12.75)
0.053 (1.36)
All Dimensions in Inches [mm]
0.069 (1.74)
0.197 (5.00)
0.394 (10.01)
1.181 (30.00)
1.378 (35.00)
0.100 (2.54)
12 places
0.063 (1.60)
0.053 (1.36)
1.181 (30.00)
1.378 (35.00)
Datasheet © Artesyn Technologies
®
2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
NNootteess
1 Measured as per recommended set-up. See Application Note 116 for details.
2 di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
3 The SXE15 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 116 for details.
4 Recommended input fusing is a 2 A HRC 200 V rated fuse.
5 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
6 Measured with external Pi filter. See Application Note 116 for further details.
7 Start-up into resistive load.
8 Active low remote on/off is available. Standard product is active high.
Designate with the Suffix ‘-R’ e.g. SXE15-48S05-RJ.
9 Operating ambient temperatures are specified at natural convection.
Higher operating temperatures are possible with increased airflow.
See Application Note 116 for further details.
10 SXE15-48S12J below 0.2 A loading. OVP is TVS and 17 V typical.
11 Signal line assumed < 3 m in length.
12 A 5% minimum load is required to maintain the output voltage regulation
over all operating conditions for the SXE15-48S12J.
13 This parameter is calculated at worst case line, load,
temperature and initial settings.
14 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
15 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
PROTECTION
Short circuit Continuous
Overvoltage Latching clamp
TELECOM SPECIFICATION
Central office interface A ETS300-132-2, input voltage
and current requirements
PIN CONNECTIONS
PIN NUMBER FEATURE
1 Vout +
2 Vout -
3 N/C
4 Trim
5 N/C
6 N/C
7 N/C
8 On/Off
9 N/C
10 N/C
11 Vin -
12 Vin +
SXE15 Series
Single output
Please consult our website for the following items: Application Note Longform Data Sheet
www.artesyn.com
International Safety Standard Approvals
UL/cUL 1950 3rd edition. File No. E135734
TÜV TÜV Rheinland. File No. 10401-3336-35841. Licence No. 40004290
OUTPUT
INPUT
OVP
OUTPUT
OUTPUT OUTPUT
EFFICIENCY
REGULATION
MODEL
POWER
VOLTAGE VOLTAGE
CURRENT CURRENT
(TYP.)
LINE LOAD
NUMBER
(8,14,15)
(MAX.) (MIN.) (MAX.)
10.8 W 33-75 Vdc 2.3 Vdc 1.8 V 0 A 6 A 83% 0.3% 2.0% SXE15-48S1V8J
15 W 33-75 Vdc 3.2 Vdc 2.5 V 0 A 6 A 85% 0.3% 1.5% SXE15-48S2V5J
15 W 33-75 Vdc 4 Vdc 3.3 V 0 A 4.5 A 86% 0.1% 0.5% SXE15-48S3V3J
15 W 33-75 Vdc 6 Vdc 5 V 0 A 3 A 87% 0.1% 0.5% SXE15-48S05J
15 W 33-75 Vdc 15 Vdc
(10)
12 V 0 A 1.25 A 85% 0.1% 0.5% SXE15-48S12J
File Name: sxe15s.pdf Rev (02): 08 Dec 2005

SXE15-48S3V3-R

Mfr. #:
Manufacturer:
Description:
DC DC CONVERTER 3.3V 15W
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union