SPECIFICATION
PS-45-3.3 PS-45-5 PS-45-7.5 PS-45-12 PS-45-13.5 PS-45-15 PS-45-24 PS-45-27 PS-45-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
AC CURRENT (Typ.)
3.3V
5V 7.5V 13.5V 15V 24V 27V 48V
8A 8A 5.4A 3A 1.9A 1.7A 1A
0 ~ 10.7A 0 ~ 10.5A 0 ~ 7A 0 ~ 4.4A 0 ~ 3.9A 0 ~ 3.5A 0 ~ 2.2A 0 ~ 1.95A 0 ~ 1.1A
26.4W
Rated output power for convection; 52W (+3.3V : 35W) with 18 CFM min.
40W 40.5W 44.4W 44.55W 45W 45.6W 45.9W 48W
80mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.85V 14.25 ~ 16.5V 22.8 ~ 26.4V 25.65 ~ 29.7V 45.6 ~ 52.8V
±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0%
800ms, 30ms at full load
60ms at full load
90 ~ 264VAC 127 ~370VDC
47 ~ 440Hz
69% 74% 75% 77% 78% 78% 78%
0.8A/115VAC 0.56A/230VAC
COLD START 15A/115VAC 30A/230VAC
<0.75mA / 240VAC
53 ~ 75W(3.3V : 36 ~ 55W) rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
-10 ~ +60 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH℃
±℃ ℃0.05%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
300.7K hrs min. MIL-HDBK-217F (25 )℃
127*76*28mm (L*W*H)
0.19Kg; 72pcs/15.6Kg/1.35CUFT
File Name:PS-45-SPEC 2017-07-07
3.8 ~ 4.46V 5.75 ~ 6.75V 8.63 ~ 10.1V 13.8 ~ 16.2V 15.5 ~ 18.2V
17.25 ~ 20.25V
27.6 ~ 32.4V 31 ~ 36.45V
55.2 ~ 64.8V
OVER VOLTAGE
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
45W Single Output Switching Power Supply
Universal AC input/Full range
Low leakage current<0.75mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
■
Features :
PS-45 series
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
6. Heat Sink HS1,HS2 can not be shorted.
OUTPUT POWER (max.)
12V
3.7A 3.3A
76% 77%
EMC IMMUNITY
EMC EMISSION