2297387

PHOENIX CONTACT Inc., USA Page 1 / 4
http://www.phoenixcon.com May 6, 2011
Extract from the online
catalog
ELR W2+1-230AC/500AC-37
Order No.: 2297387
The figure shows version: ELR W2+1- 24DC/500AC-37
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2297387
Three-phase solid-state reversing contactor with 230 V AC input, 37 A
output current, zero voltage switch, optionally with thermal fuse
Commercial data
GTIN (EAN)
4 046356 175746
Note Made-to-order
sales group G424
Pack 1 pcs.
Customs tariff 85364900
Catalog page information Page 167 (IF-2009)
Product notes
WEEE/RoHS-compliant since:
05/29/2008
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
Input data
Mains frequency 50 Hz
60 Hz
Rated actuating voltage U
C
230 V AC (Ensure phase balance)
ELR W2+1-230AC/500AC-37 Order No.: 2297387
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2297387
PHOENIX CONTACT Inc., USA Page 2 / 4
http://www.phoenixcon.com May 6, 2011
Rated actuating voltage range with reference to
U
C
0.4 ... 1.1
Rated actuating current I
C
11.2 mA
Switching threshold "0" signal, voltage 48 V AC
Switching threshold "1" signal voltage 96 V AC
Protective circuit Surge protection Varistor
Status display Yellow LED
Indication Red LED
Output data, load relay
Output name AC output
Nominal output voltage 500 V AC
Nominal output voltage range 48 V AC ... 575 V AC
Periodic peak reverse voltage 1200 V
Load current max. 37 A (see derating curve)
Leakage current 6 mA
Residual voltage < 1.5 V
Surge current 1300 A (t = 10 ms)
Max. load value
9000 A
2
s
Type of protection RCV circuit
Surge voltage protection > 575 V AC
General data
Width 147.5 mm
Height 99 mm
Depth 114.5 mm
Test voltage input/output 5 kV
rms
Ambient temperature (operation) -25 °C ... 70 °C
Ambient temperature (storage/transport) -25 °C ... 70 °C
Mounting position Vertical (horizontal DIN rail)
Assembly instructions Can be aligned with spacing = 40 mm
Operating mode 100% operating factor
Degree of protection IP20
Name Standards/regulations
Standards/regulations DIN EN 50178
EN 60947
Name Power station requirements
ELR W2+1-230AC/500AC-37 Order No.: 2297387
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2297387
PHOENIX CONTACT Inc., USA Page 3 / 4
http://www.phoenixcon.com May 6, 2011
Standards/regulations DWR 1300 / ZXX01/DD/7080.8d
Name Air and creepage distances between the power circuits
Standards/regulations DIN EN 50178
Rated surge voltage / insulation 6 kV / Basic isolation
Rated insulation voltage 500 V
Pollution degree 2
Surge voltage category III
Certificates / Approvals
Certification CUL Listed, UL Listed
Certifications applied for: GL
Diagrams/Drawings
Block diagram
Diagram

2297387

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Solid State Relays - Industrial Mount ELR W2+1-230AC/ 500AC-37
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet