12/21/2012 - 2 - www.onsemi.com
Test Procedure:
1. Connect the test setup as shown above.
2. Make sure the load is not enabled.
3. Apply an enable voltage V
EN
=0V. Apply an input voltage, V
IN
= 13.2 V. V
OUT
should
be 0V.
4. Apply an enable voltage V
EN
=3V. Verify that the output voltage is 3.3 V +/-0.15 V.
5. Set up the load to 1.2A and enable it. Verify that the output voltage is still 3.3 V +/-
0.15 V.
6. Change the input voltage to 36 V. Verify that the output voltage is 0 V.
7. Change the input voltage to 6 V. Verify that the output voltage is 3.3 V +/-0.15 V.
8. Change the input voltage to 3.9 V. Verify that the output voltage is 0 V.
9. Change the input voltage to 6 V. Verify that the output voltage is 3.3 V +/-0.15 V.
10. Apply an enable voltage V
EN
=0V. V
OUT
should be 0V.
11. Turn off the DC sources.