JV RELAYS
FLAT TYPE POWER RELAY
10.9
.429
16
.630
22
.866
mm inch
FEATURES
• Flat type: 16 mm (length)
×
22 mm (width)
×
10.9 mm (height)
(.630
×
.866
×
.429 inch)
• High capacity type (16A) available
• High sensitivity type (100 mW: 1 Form A) available
• TÜV also approved
SPECIFICATIONS
Contact
Coil
Standard type
High capacity
type
High
sensitivity type
Arrangement 1 Form A 1 Form C 1 Form A 1 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
50 m
Ω
Contact material Silver alloy
Rating
(resistive)
Nominal switching
capacity
10 A 125 V AC
10 A 125 V AC (N.O.)
6 A 125 V AC (N.C.)
16 A 125 V AC 10 A 125 V AC
Max. switching power 1,250 VA
1,250 VA (N.O.)
750 VA (N.C.)
2,000 VA 1,250 V
Max. switching voltage 125 V AC
Max. switching current 10 A
10 A (N.O.)
6 A (N.C.)
16 A 10 A
Expected life (min. ope.)
Mechanical at (180 cpm)
10
7
Electrical at resistive
(at 20 cpm)
(at rated load)
Sealed type 10
5
10
5
3
×
10
4
5
×
10
4
Flux-resistant
type
3
×
10
5
10
5
10
5
10
5
1 Form A type 1 Form C type
Nominal
operating
power
Standard type
200 mW (up to 48 V coil type)
600 mW (100 V coil type)
400 mW (up to 48 V coil type)
600 mW (100 V coil type)
High capacity type —
High sensitivity type 100 mW —
Characteristics
Max. operating speed 20 cpm
Initial insulation resis-
tance*
1
Min. 100 M
Ω
(at 500 V DC)
Initial
break-
down
voltage*
2
Between open
contacts
1,000 Vrms
for 1 min.
Between con-
tacts and coil
1,500 Vrms
for 1 min.
Operate time*
3
(at nominal voltage)
Approx. 10 ms
Approx. 5 ms
(100 V DC coil type)
Release time (without diode)*
3
(at nominal voltage)
Approx. 4 ms
Temperature rise
(at 50°C)
Max. 65
°
C with nominal
coil voltage across
coil and at nominal
switching capacity
Shock
resistance
Functional*
4
Min. 98 m/s
2
{10 G}
Destructive*
5
Min. 980 m/s
2
{100 G}
Vibration
resistance
Functional*
6
10 to 55 Hz
at double amplitude
of 1.0 mm
Destructive
10 to 55 Hz
at double amplitude
of 1.6 mm
Conditions for opera-
tion, transport and
storage*
7
(Not freezing and
condensing at low
temperature)
Ambient
temp.
–40
°
C to +70
°
C*
8
–40
°
F to +158
°
F
Humidity 5 to 85%R.H.
Unit weight Approx. 8 g .282 oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage"section
*
2
Detection current: 10mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms, detection time: 10
µ
s
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10
µ
s
*
7
Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT .
*
8
100V type: –40 to + 60
°
C –40 to + 140
°
F
TYPICAL APPLICATIONS
1. Home appliances: Air conditioner, heater, etc.
2. Automotive: Power supply for car stereo and air conditioner
ORDERING INFORMATION
Contact arrangement
1: 1 Form C
1a: 1 Form A
Nil: Standard type
P: High capacity type*
Nil: Sealed type
F: Flux-resistant type
Nil: Standard type
(1 Form A: 200 mW, 1Form C: 400 mW
100 V DC coil type: 600 mW)
S: High sensitivity type*
(1 Form A: 100 mW)
Rating Protective construction Sensitivity Coil voltage (DC)
5, 6, 9, 12, 18,
24, 48, 100V
Ex. JV 1a P F S 12V
* Only for 1 Form A typeNotes:
UL/CSA, TÜV approved type is standard.
1. Standard packing: Carton: 50 pcs.; Case: 1,000 pcs.
2. Coil voltage DC 48, 100 V types are not available for high sensitivity type.