Additional Application Fault Ratings at 20°C
I) Power contact: 250 V
RMS
, 10load in series with TRF250-184, 1 application, t = 15 min (see Test Schematic 1 below).
– Meets Acceptance Criterion A or B of ITU-T K.20, K.21.
Test Schematic 1: 250 V
RMS
, 10load in series with TRF250-184:
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------
II) Power contact: 250 V
RMS
, sequentially testing at 10204080160300600 in series with TRF250-184 & SiBar
TM
devices,
total 7 applications, t = 2 min at each load, 5 min wait between applications (see Test Schematic 2 below).
– Tested (a) to (b) with ungrounded circuit.
– Tested either transversely [ a- terminal and ground together to b- terminal,
b-terminal and ground together to a- terminal ], or port-to-earth [ (a and b) together to ground with grounded circuit.
– Meets Acceptance Criterion A or B of ITU-T K.20, K.21.
Test Schematic 2: 250 V
RMS
, 10 to 600load in series with TRF250-184 & SiBar devices:
Ungrounded circuit Grounded circuit
Note:
1) SiBar device (TVB275NSB-L): V
DM
= 275V maximum, V
BO
= of 350V maximum, I
PP
= 100A (V
OC
10/700s).
III) Power induction (10A
2
s): 447
RMS
(t = 2.0s) to 1500 V
RMS
(t=0.18s), 200load in series with TRF250-184 & SiBar devices with primary
protection, 5 applications, 1 min wait between applications (see Test Schematic 3 below).
– Tested (a) to (b) with ungrounded circuit.
– Tested either transversely [ a- terminal and ground together to b- terminal,
b-terminal and ground together to a- terminal ], or port-to-earth [ (a and b) together to ground with grounded circuit.
– Meets Acceptance Criterion A or B of ITU-T K.20, K.21.
Test Schematic 3: 447
RMS
(t = 2.0s) to 1500 V
RMS
(t=0.18s), 200load in series with TRF250-184, SiBar, GDT devices:
Ungrounded circuit Grounded circuit
Note:
1) SiBar device (TVB275NSB-L): V
DM
= 275V maximum, V
BO
= of 350V maximum, I
PP
= 100A (V
OC
10/700s)
2) GDT device (GTCA28-421M-R10 for ungrounded circuit and GTCR(A)38-421M-R10 for grounded circuit): Nominal DC sparkover
voltage = 420V @100V/s