Turquoise Stroke Switches (ASQ1)
–2–
AECTB6E 201701-T
■ Wire leads bottom type (Mounting hole 3mm standard type)
■ Wire leads side type (Mounting hole 3mm standard type)
SPECIFICATIONS
■ Contact rating
1 mA 5 V DC to 100 mA 30 V DC
Note: Please consult us regarding 42 V DC rating.
■ Operation environment and conditions
Note: When switching at low and high speeds or under vibration, or in high-temperature, high-humidity environments, life and performance may be reduced significantly
depending on the load capacity. Please consult us.
■ Electrical characteristics
■ Characteristics
Note: As long as there are no particular designations, the following conditions apply to the test environment.
• Ambient temperature: 5 to 35°C
• Relative humidity: 25 to 85% RH
• Air pressure: 86 to 106 kPa
Note 1: Switching life for single switching (COM-NC or COM-NO connection) and double switching (COM-NC and COM-NO connection).
Note 2: Switching life is for single switching life. For double switching it is greater than 100,000 times.
Actuator Operating Force OF (Max.)
Wire leads bottom type (Mounting hole 3mm standard type)
SPDT SPST-NC SPST-NO
Pin plunger 1.5N ASQ10610 ASQ10620 ASQ10630
Leaf lever 1.7N ASQ10617 ASQ10627 ASQ10637
Simulated leaf lever 1.5N ASQ10618 ASQ10628 ASQ10638
Actuator Operating Force OF (Max.)
Wire leads right side type
(Mounting hole 3mm standard type)
Wire leads left side type
(Mounting hole 3mm standard type)
SPST-NC SPST-NO SPST-NC SPST-NO
Pin plunger 1.5N ASQ10220 ASQ10230 ASQ10320 ASQ10330
Leaf lever 1.7N ASQ10227 ASQ10237 ASQ10327 ASQ10337
Simulated leaf lever 1.5N ASQ10228 ASQ10238 ASQ10328 ASQ10338
Item Specifications
Ambient and storage temperature –40°C to +85°C (no freezing and condensing)
Allowable operating speed 30 to 500 mm/sec.
Max. operating cycle rate 120 cpm
Dielectric strength (Initial)
Between non-continuous terminals: 600 Vrms, Between each terminal and other exposed metal parts: 1,500 Vrms,
Between each terminal and ground: 1,500 Vrms (at detection current of 1 mA)
Insulation resistance (Initial) Min. 100 MΩ (at 500 V DC insulation resistance meter) (Locations measured same as dielectric strength.)
Contact resistance (Initial) Max. 1 Ω (by voltage drop 0.1 A 6 to 8 V DC)
Item Specifications
Electrical
switching
life
5 V DC 1 mA (Resistive load) Min. 5 × 10
5 Note 1)
Switching frequency: 20 times/min.
Conduction ratio: 1:1
Pushbutton operation speed: 100 mm/s
Pushbutton switching position: free position (FP) to operation limit position (TTP)
16 V DC 50 mA (Resistive load) Min. 5 × 10
5 Note 2)
30 V DC 100 mA (Resistive load) Min. 2 × 10
5 Note 2)
Vibration resistance
(malfunction vibration resistance)
Single amplitude: 0.75 mm
Amplitude of vibration: 10 to 55 Hz (4 minutes cycle)
Direction and time: 30 minutes each in X, Y and Z directions
Amplitude of vibration: 5 to 200 Hz (10 minutes cycle)
Acceleration: 43.1 m/s
2
Direction and time: 30 minutes each in X, Y and Z directions
Shock resistance
(malfunction shock resistance)
Shock value: 980 m/s
2
Direction and time: 5 times each in X, Y and Z directions
Vibration resistance endurance
Frequency of vibration: 33.3 Hz, Acceleration: 43.1 m/s
2
Direction and time: 8 hours each in X, Y and Z directions
Terminal strength 6 N min. (each direction) *Terminal deformation possible.
Heat resistance 85°C 500 hours
Cold resistance –40°C 500 hours
Humidity resistance 40°C 95% RH 500 hours
Thermal shock resistance 30 min. at 85°C to 30 min at –40°C for 1,000 cycles
Unit weight Approx. 0.8 g (terminal type), Approx. 5.4 g (wire leads side type)
Protection grade IP67 (except exposed terminal part of terminal type)