DCDC
40 Watts
• 2:1 Input Range
• Single, Dual & Triple Outputs
• 40 °C to +100 °C Operating Temperature
• High Efficiency up to 92%
•
Sixsided Metal Case
• Fixed 350 kHz Switching Frequency
• 3 Year Warranty
JCP Series
Input
Input Voltage Range • 12 VDC (9-18 VDC)
24 VDC (18-36 VDC)
48 VDC (36-75 VDC)
Input Current • See table
Input Filter • Pi network
Undervoltage Lockout • Turn on >71% nominal input
Turn off <67% nominal input
Output
Output Voltage • See table
Output Voltage Trim • ±10%
Minimum Load • See table
Line Regulation • ±0.5% max for single & dual output,
±1.0% max for V1 of triple output,
±3.0% for aux of triple output
Load Regulation • ±0.5% max single ±1.0% dual output,
±1.0% max for V1 of triple output,
±4.0% for aux of triple output
Setpoint Accuracy • ±1.5% max single and dual
±1.5% max for V1, ±3.0% of triple output
Voltage Balance • ±2.0% max
Ripple & Noise • 2.5, 3.3 & 5.0 V models 50 mV pk-pk max
12.0 & 15.0 V models 75 mV pk-pk max
(20 MHz bandwidth)
Transient Response • 5% max deviation, recovery to within
1% in 300 µs for a 25% load change
Temperature • ±0.02%/°C
Coefficient
Overvoltage Protection • 2.5 V models 3.6 V typical,
3.3 V models 3.9 V typical,
5.0 V models 6.2 V typical,
12.0 V models 15.0 V typical,
15.0 V models 18.0 V typical
Overcurrent Protection • 110-140%
Short Circuit Protection • Continuous, trip & restart (Hiccup mode)
Remote On/Off • ON >3.5 to 75 VDC or open circuit
OFF <1.8 VDC
Thermal Protection • Shuts down when case temperature
measures +110 °C typical
Remote Sense • Compensates for up to 10% voltage drop
single output models only
xppower.com
General
Efficiency • See table
Isolation Voltage • 1500 VDC Input to Output
1500 VDC Input to Case
Output return connected to case
Switching Frequency • 350 kHz typical
MTBF • >600 kHrs to MIL-HDBK-217F,
GB at 25 º C
Isolation Resistance • 10
9
min
Environmental
Operating Temperature • -40 °C to +100 °C, derate from 100% load
at +60 °C to 0% load at +100 °C
Case Temperature • +100 °C max
Storage Temperature • -55 °C to +125 °C
Cooling • Convection-cooled
Operating Humidity • Up to 90%, non-condensing
Shock • 30 g, half sine wave 18 ms pulse applied
3 times on each of 6 axes
Vibration • 5-500 Hz, 3 g, for 10 mins on each
of 3 axes
EMC & Safety
Emissions • EN55022 Level A conducted & radiated
with external components - contact
technical sales
ESD Immunity • EN61000-4-2, Level 2 Perf Criteria A
Radiated Immunity • EN61000-4-3, 3 V/m Perf Criteria A
Conducted Immunity • EN61000-4-6, 3 V rms Perf Criteria A