55PC6273-12-9-9CS3199

Page 16 of 18 SPECIFICATION 55PC, ISSUE 8
NOTE: ANY PRINTED COPY OF THIS DOCUMENT
IS AN UNCONTROLLED COPY.
© 2008-2015 Tyco Electronics Corporation. All rights reserved.
5. STANDARD PACKAGING
Unless otherwise specified (see 7.1), the following shall define the standard spooling and
labeling requirements for wire and cable furnished under this specification. Standard shipping
tolerance on ordered quantity, for both wire and cable, shall be ± 10 percent.
5.1 SPOOLING REQUIREMENTS
All layers of wire and cable shall be wound on spools or reels (see 5.1.3) with sufficient
tension to prevent shifting of layers and creation of crossovers within layers.
5.1.1 Finished Wire
Finished wire lengths shall be wound on spools or reels with the ends spliced together to
provide one mechanically and electrically continuous length. Unless otherwise specified, the
minimum continuous length between splices shall be in accordance with Table 5.
TABLE 5. FINISHED WIRE LENGTHS
Wire Size Range
(AWG)
Minimum Length
30 through 10
8 and larger
100 feet (30 m)
50 feet (15 m)
(NOTE: Metric lengths specified above apply only to those orders placed in metric.)
5.1.2 Finished Cable
Finished cable lengths shall be wound on spools or reels with all ends exposed. There shall be
no more than 5 lengths per spool or reel and no length shall be less than 50 feet (15 m).
5.1.3 Spools and Reels
Spools and reels shall be of a nonreturnable type. Each spool and reel shall have an
appropriate diameter for the respective wire or cable size. In no case shall the barrel of the
spool or reel have a diameter less than 3.5 inches (89 mm). Spools and reels shall be suitably
finished to prevent corrosion under typical storage and handling conditions. Loaded plastic
spools shall not exceed 50 pounds (23 kg). Loaded wooden reels shall have no weight
restriction.
5.1.4 Containers
Unless otherwise specified (see 7.1), finished wire and cable shall be delivered in standard
commercial containers so constructed as to ensure acceptance by common or other carrier for
safe transportation at the lowest rate to the point of delivery.
SPECIFICATION 55PC, ISSUE 8 Page 17 of 18
NOTE: ANY PRINTED COPY OF THIS DOCUMENT
IS AN UNCONTROLLED COPY.
© 2008-2015 Tyco Electronics Corporation. All rights reserved.
5.2 LABELING REQUIREMENTS
All spools and reels shall be identified with the following information:
Manufacturer's Part Number
Lot Number
Quantity in Feet (or Meters)
Name of Manufacturer
6. APPLICABLE DOCUMENTS
6.1 GOVERNMENT-FURNISHED DOCUMENTS
The following documents, of the issue in effect on date of invitation for bids or request for
proposal, form a part of this specification to the extent specified herein.
6.1.1 Department of Defense
SPECIFICATIONS
Federal
UU-T-450 Tissue, Facial
STANDARDS
Military
MIL-STD-104 Limits for Electrical Insulation Color
MIL-STD-1916 DOD Preferred Methods for Acceptance of Product
(Copies of Department of Defense documents may be obtained from the Naval Publications
and Forms Center, Standardization Documents Order Desk, Bldg. 4D, 700 Robbins Ave.,
Philadelphia, PA 19111-5094; or at http://assist.daps.dla.mil/quicksearch/.)
6.2 OTHER PUBLICATIONS
The following documents, of the issue in effect on date of invitation for bids or request for
proposal, form a part of this specification to the extent specified herein.
6.2.1 American Society for Testing and Materials (ASTM)
B 193 Standard Test Method for Resistivity of Electrical Conductor Materials
D 3032 Standard Test Methods for Hookup Wire Insulation
(Copies of ASTM documents may be obtained from the American Society for Testing and
Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959; or at
www.astm.org.)
Page 18 of 18 SPECIFICATION 55PC, ISSUE 8
NOTE: ANY PRINTED COPY OF THIS DOCUMENT
IS AN UNCONTROLLED COPY.
© 2008-2015 Tyco Electronics Corporation. All rights reserved.
6.2.2 International Organization for Standardization (ISO)
8402 Quality Management and Quality Assurance - Vocabulary
(Copies of ISO documents may be obtained from the International Organization for
Standardization; or at www.iso.org.)
6.2.3 National Electrical Manufacturers Association (NEMA)
WC 27500 Standard for Aerospace and Industrial Electrical Cable
(Copies of NEMA documents may be obtained from the National Electrical Manufacturers
Association, 1300 North 17th Street, Rosslyn, VA 22209; or at www.nema.org.)
6.2.4 Society of Automotive Engineers (SAE)
AS22759 Wire, Electrical, Fluoropolymer-Insulated, Copper or Copper Alloy
(Copies of SAE documents may be obtained from the Society of Automotive Engineers,
400 Commonwealth Drive, Warrendale, PA 15096-0001; or at www.sae.org.)
7. NOTES
7.1 ORDERING DATA
Procurement documents should specify the following:
a. Title, number, and revision of this specification
b. Applicable SCD part number and color code (see 1.3)
c. Quantity
d. Special preparation for delivery requirements, if applicable (see Section 5)
7.2 METRIC UNITS
Metric units (where shown in parentheses) are for information only.
7.3 TRADEMARKS
Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks.