www.fairchildsemi.com 4
74F646
AC Electrical Characteristics
AC Operating Requirements
Symbol Parameter
T
A
= +25°CT
A
= −55°C to +125°CT
A
= 0°C to +70°C
Units
V
CC
= +5.0V V
CC
= +5.0V V
CC
= +5.0V
C
L
= 50 pF C
L
= 50 pF C
L
= 50 pF
Min Max Min Max Min Max
f
MAX
Maximum Clock Frequency 90 75 90 MHz
t
PLH
Propagation Delay 2.0 7.0 2.0 8.5 2.0 8.0
ns
t
PHL
Clock to Bus 2.0 8.0 2.0 9.5 2.0 9.0
t
PLH
Propagation Delay 1.0 7.0 1.0 8.0 1.0 7.5
ns
t
PHL
Bus to Bus 1.0 6.5 1.0 8.0 1.0 7.0
t
PLH
Propagation Delay 2.0 8.5 2.0 11.0 2.0 9.5
ns
t
PHL
SBA or SAB to A or B 2.0 8.0 2.0 10.0 2.0 9.0
t
PZH
Enable Time 2.0 8.5 2.0 10.0 2.0 9.0
ns
t
PZL
OE to A or B 2.0 12.0 2.0 13.5 2.0 12.5
t
PHZ
Disable Time 1.0 7.5 1.0 9.0 1.0 8.5
ns
t
PLZ
OE to A or B 2.0 9.0 2.0 11.0 2.0 9.5
t
PZH
Enable Time 2.0 14.0 2.0 16.0 2.0 15.0
ns
t
PZL
DIR to A or B 2.0 13.0 2.0 15.0 2.0 14.0
t
PHZ
Disable Time 1.0 9.0 1.0 10.0 1.0 9.5
ns
t
PLZ
DIR to A or B 2.0 11.0 2.0 12.0 2.0 11.5
Symbol Parameter
T
A
= +25°CT
A
= −55°C to +125°CT
A
= 0°C to +70°C
UnitsV
CC
= +5.0V V
CC
= +5.0V V
CC
= +5.0V
Min Max Min Max Min Max
t
S
(H) Setup Time, HIGH or LOW 5.0 5.0 5.0
ns
t
S
(L) Bus to Clock 5.0 5.0 5.0
t
H
(H) Hold Time, HIGH or LOW 2.0 2.5 2.0
ns
t
H
(L) Bus to Clock 2.0 2.5 2.0
t
W
(H) Clock Pulse Width 5.0 5.0 5.0
ns
t
W
(L) HIGH or LOW 5.0 5.0 5.0