HCPL-M601-500E

4
Insulation and Safety Related Specifications
Parameter Symbol Value Units Conditions
Minimum External Air Gap
(External Clearance)
L(101) 5 mm Measured from input terminals to output terminals,
shortest distance through air.
Minimum External
Tracking (External Creepage)
L(102) 5 mm Measured from input terminals to output terminals,
shortest distance path along body.
Minimum Internal Plastic Gap
(Internal Clearance)
0.08 mm Through insulation distance conductor to conductor,
usually the straight line distance thickness between
the emitter and detector.
Tracking Resistance
(Comparative Tracking Index)
CTI 175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060)
Description Symbol Characteristic Unit
Installation classification per DIN VDE 0110/39, Table 1
for rated mains voltage
d 150 Vrms
for rated mains voltage
d 300 Vrms
I – IV
I – III
Climatic Classification 55/85/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
560 Vpeak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875=V
PR
, 100% Production Test with tm=1 sec,
Partial discharge < 5 pC
V
PR
1050 Vpeak
Input to Output Test Voltage, Method a*
V
IORM
x 1.5=V
PR
, Type and Sample Test, tm=60 sec,
Partial discharge < 5 pC
V
PR
840 Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage t
ini
=10 sec)
V
IOTM
6000 Vpeak
Safety-limiting values – maximum values allowed in the event
of a failure.
Case Temperature
Input Current**
Output Power**
T
S
I
S, INPUT
P
S, OUTPUT
150
150
600
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
:
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/
EN/DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
** Refer to the following figure for dependence of P
S
and I
S
on ambient temperature.
Recommended Operating Conditions
Parameter Symbol Min. Max. Units
Input Current, Low Level I
FL
* 0 250 μA
Input Current, High Level I
FH
** 5 15 mA
Supply Voltage, Output V
CC
4.5 5.5 V
Fan Out (R
L
= 1 kΩ) N 5 TTL Loads
Output Pull-Up Resistor R
L
330 4,000 Ω
Operating Temperature T
A
-40 85 °C
* The off condition can also be guaranteed by ensuring that V
F
(off) ≤ 0.8 volts.
** The initial switching threshold is 5mA or less. It is recommended that 6.3mA to 10mA be used for best performance and to permit at least a
20% LED degradation guardband.
5
Absolute Maximum Ratings
(No Derating Required up to 85°C)
Parameter Abs. Max.
Storage Temperature -55°C to +125°C
Operating Temperature -40°C to +85°C
Forward Input Current - I
F
(see Note 2) 20 mA
Reverse Input Voltage - V
R
5 V
Supply Voltage - V
CC
(1 Minute Maximum) 7 V
Output Collector Current - I
O
50 mA
Output Collector Power Dissipation 85 mW
Output Collector Voltage - V
O
(Selection for higher output voltages up to 20 V is available)
7 V
Infrared and Vapor Phase Reflow Temperature see below
Solder Reflow Thermal Profile
Recommended Pb-Free IR Profile
Note: Non-halide flux should be used.
Note: Non-halide flux should be used.
0
TIME (SECONDS)
TEMPERATURE (°C)
200
100
50 150100 200 250
300
0
30
SEC.
50 SEC.
30
SEC.
160°C
140°C
150°C
PEAK
TEMP.
245°C
PEAK
TEMP.
240°C
PEAK
TEMP.
230°C
SOLDERING
TIME
200°C
PREHEATING TIME
150°C, 90 + 30 SEC.
2.5°C ± 0.5°C/SEC.
3°C + 1°C/–0.5°C
TIGHT
TYPICAL
LOOSE
ROOM
TEMPERATURE
PREHEATING RATE 3°C + 1°C/–0.5°C/SEC.
REFLOW HEATING RATE 2.5°C ± 0.5°C/SEC.
217 °C
RAMP-DOWN
6 °C/SEC. MAX.
RAMP-UP
3 °C/SEC. MAX.
150 - 200 °C
260 +0/-5 °C
t 25 °C to PEAK
60 to 150 SEC.
20-40 SEC.
TIME WITHIN 5 °C of ACTUAL
PEAK TEMPERATURE
t
p
t
s
PREHEAT
60 to 180 SEC.
t
L
T
L
T
smax
T
smin
25
T
p
TIME
TEMPERATURE
NOTES:
THE TIME FROM 25 °C to PEAK
TEMPERATURE = 8 MINUTES MAX.
T
smax
= 200 °C, T
smin
= 150 °C
6
Insulation Related Specifications
Parameter Symbol Value Units Conditions
Min. External Air Gap L(IO1) ≥5 mm Measured from input terminals
(Clearance) to output terminals
Min. External Tracking Path L(IO2) ≥5 mm Measured from input terminals
(Creepage) to output terminals
Min. Internal Plastic Gap 0.08 mm Through insulation distance
(Clearance) conductor to conductor
Tracking Resistance CTI 175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group (per DIN VDE 0109) IIIa Material Group DIN VDE 0109
Electrical Specifications
Over recommended temperature (T
A
= -40°C to 85°C) unless otherwise specified. (See note 1.)
Parameter Symbol Min. Typ.* Max. Units Test Conditions Fig. Note
Input Threshold I
TH
2 5 mA V
CC
= 5.5 V, I
O
≥13 mA, 13
Current V
O
= 0.6 V
High Level Output I
OH
5.5 100 μA V
CC
= 5.5 V, V
O
= 5.5 V 1
Current I
F
= 250 μA
Low Level Output V
OL
0.4 0.6 V V
CC
= 5.5 V, I
F
= 5 mA, 2, 4,
Voltage I
OL
(Sinking) = 13 mA 5, 13
High Level Supply I
CCH
4 7.5 mA V
CC
= 5.5 V, I
F
= 0 mA,
Current
Low Level Supply I
CCL
6 10.5 mA V
CC
= 5.5 V, I
F
= 10 mA,
Current
Input Forward V
F
1.4 1.75 V T
A
= 25°C, I
F
=10 mA 3
Voltage 1.5
1.3 1.85 I
F
= 10 mA
Input Reverse BV
R
5 I
R
= 10 μA
Breakdown Voltage
Input Capacitance C
IN
60 pF V
F
= 0V, f = 1 MHz
Input Diode V
F
/∆T
A
-1.6 mV/°C I
F
= 10 mA 12
Temperature
Coefficient
Input-Output V
ISO
3750 V
RMS
RH ≤ 50%, t = 1 min. 3, 4
Insulation
Resistance R
I-O
10
12
Ω V
I-O
= 500 V 3
(Input-Output)
Capacitance C
I-O
0.6 pF f = 1 MHz 3
(Input-Output)
*All typicals at T
A
= 25°C, V
CC
= 5 V.

HCPL-M601-500E