VND830PEP-E Electrical specifications
Doc ID 10826 Rev 6 9/25
Figure 4. Open-load status timing (with external pull-up)
T
hyst
Thermal hysteresis 7 15 °C
t
SDL
Status delay in overload
conditions
T
j
> T
TSD
20 µs
I
lim
Current limitation
5.5V < V
CC
< 36V
6915
15
A
A
V
demag
Turn-off output clamp voltage I
OUT
= 2A; L = 6mH
V
CC
-
41
V
CC
-
48
V
CC
-
55
V
1. To ensure long term reliability under heavy overload or short circuit conditions, protection and related
diagnostic signals must be used together with a proper software strategy. If the device is subjected to
abnormal conditions, this software must limit the duration and number of activation cycles.
Table 11. Open-load detection
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
OL
Open-load on-state
detection threshold
V
IN
= 5V 50 100 200 mA
t
DOL(on)
Open-load on-state
detection delay
I
OUT
= 0A 200 µs
V
OL
Open-load off-state
voltage detection
threshold
V
IN
= 0V 1.5 2.5 3.5 V
t
DOL(off)
Open-load detection
delay at turn-off
1000 µs
Table 10. Protections
(1)
(continued)
Symbol Parameter Test conditions Min. Typ. Max. Unit
Obsolete Product(s) - Obsolete Product(s)