© 2013 International Rectifier
Recommended Operating Conditions
For proper operation, the device should be used within the recommended conditions below. The Vs and COM
offset ratings are tested with supplies biased at V
AA
-V
SS
=10 V, V
CC
=12 V and V
B
-V
S
=12 V. All voltage parameters
are absolute voltages referenced to COM; all currents are defined positive into any lead.
High side floating supply absolute voltage
High side floating supply offset voltage
Floating input positive supply zener clamp current
Floating input negative supply zener clamp current
Floating input supply absolute voltage
High side floating output voltage
Low side fixed supply voltage
COMP pin phase compensation capacitor to GND
Reference output current to COM
††
Allowable Vss voltage slew rate upon power-up
††††
Logic operational for Vs equal to –5 V to +200 V. Logic state held for Vs equal to –5 V to –V
BS
.
Nominal voltage for V
REF
is 5.1 V. I
OREF
of 0.3 – 0.8 mA dictates total external resistor value on VREF
to be 6.3 kΩ to 16.7 kΩ.
GND input voltage is limited by I
AAZ
and I
SSZ
.
V
SS
ramps up from 0 V to 200 V.
Output logic status may not respond correctly if input pulse width is smaller than the minimum pulse
width.