LC75809PT
www.onsemi.com
23
Control Data Functions
(1) P1A,P1B,P1C,P1D …………………. General-purpose output port (P1) function setting control data
P2A,P2B,P2C to P12A,P12B,P12C … General-purpose output port (P2 to P12) function setting control data
These control data bits set the general-purpose output function (High or low level output), PWM output function or
clock output function of the P1 output pin, and the general-purpose output function (High or low level output) or
PWM output function of the P2 to P12 output pins.
However, be careful of being unable to set a PWM output function when the external clock operating frequency is
set the f
CK
2=38[kHz]typ (EXF="1") in external clock operating mode (OC= "1").
In addition, be careful of setting of the general-purpose output function (High or low level output) in the case of the
simple mode transfer forcibly.
P1A P1B P1C P1D General-purpose output port (P1) function
0 0 0 0 General-purpose output function (High or low level output)
1 0 0 0 PWM output function (Ch1) (Support for PWM data W10 to W15)
0 1 0 0 PWM output function (Ch2) (Support for PWM data W20 to W25)
1 1 0 0 PWM output function (Ch3) (Support for PWM data W30 to W35)
0 0 1 0 PWM output function (Ch4) (Support for PWM data W40 to W45)
1 0 1 0 PWM output function (Ch5) (Support for PWM data W50 to W55)
0 1 1 0 PWM output function (Ch6) (Support for PWM data W60 to W65)
1 1 1 0 Clock output function (Clock frequency : fosc/2, f
CK
/2)
0 0 0 1 Clock output function (Clock frequency : fosc/8, f
CK
/8)
Note : When are setting (P1A,P1B,P1C,P1D)=(1,X,X,1), (X,1,X,1), and (X,X,1,1), the function of general-purpose
output ports P1 is set the general-purpose output function (High or low level output). X: don’t care
PnA PnB PnC General-purpose output port (P2 to P12) function
0 0 0 General-purpose output function (High or low level output)
1 0 0 PWM output function (Ch1) (Support for PWM data W10 to W15)
0 1 0 PWM output function (Ch2) (Support for PWM data W20 to W25)
1 1 0 PWM output function (Ch3) (Support for PWM data W30 to W35)
0 0 1 PWM output function (Ch4) (Support for PWM data W40 to W45)
1 0 1 PWM output function (Ch5) (Support for PWM data W50 to W55)
0 1 1 PWM output function (Ch6) (Support for PWM data W60 to W65)
Note1 : The data PnA, PnB and PnC (Note : n=2 to 12) are the control data switching the general-purpose output
function or PWM output function of the general-purpose output ports Pn (Note : n=2 to 12).
For example, if the S10/P10 output pin is set the general-purpose output port, the general-purpose output
port P10 pin is selected the PWM output function (Ch1)
when (P10A,P10B,P10C)=(1,0,0).
Note2 : When are setting (PnA,PnB,PnC)=(1,1,1) / (Note : n=2 to 12), the function of general-purpose output ports
Pn (Note : n=2 to 12) is set the general-purpose output function (High or low level output).